. 2022 Apr;33(4):725-730.
doi: 10.1111/jce.15385. Epub 2022 Jan 31.

Device-related infection associated with increased mortality risk in de novo transvenous implantable cardioverter-defibrillator medicare patients

Affiliations

Device-related infection associated with increased mortality risk in de novo transvenous implantable cardioverter-defibrillator medicare patients

Mikhael F El-Chami et al. J Cardiovasc Electrophysiol. 2022 Apr.

Abstract

Introduction: Transvenous implantable cardioverter-defibrillators (TV-ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV-ICD infection in a large Medicare population with de novo TV-ICD implants.

Methods: A survival analysis was conducted using 100% fee-for-service Medicare facility-level claims data to identify patients who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. TV-ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time-dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias.

Results: Among 26,742 Medicare patients with de novo TV-ICD, 518 (1.9%) had a device-related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV-ICD infection was associated with an increase of 2.4 (95% CI: 2.08-2.85) times in the mortality hazard ratio.

Conclusion: The rate of TV-ICD infection and associated mortality in a large, real-world Medicare population is noteworthy. The positive association between device-related infection and risk of mortality further highlights the need to reduce infections.

Keywords: ICD; infection; medicare; mortality.

PubMed Disclaimer

References

REFERENCES

    1. Al-Khatib SM, Hellkamp A, Bardy GH, et al. Survival of patients receiving a primary prevention implantable cardioverter-defibrillator in clinical practice vs clinical trials. JAMA. 2013;309(1):55-62.
    1. Ezekowitz JA, Armstrong PW, McAlister FA. Implantable cardioverter defibrillators in primary and secondary prevention: a systematic review of randomized, controlled trials. Ann Intern Med. 2003;138(6):445-452.
    1. Greenspon AJ, Patel JD, Lau E, et al. 16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008. J Am Coll Cardiol. 2011;58:1001-1006.
    1. Sohail MR, Eby EL, Ryan MP, Gunnarsson C, Wright LA, Greenspon AJ. Incidence, treatment intensity, and incremental annual expenditures for patients experiencing a cardiac implantable electronic device infection: evidence from a large US payer database 1-year post implantation. Circ Arrhythm Electrophysiol. 2016;9(8):e003929.
    1. El-Chami MF, Jacobsen CM, Griffiths RI, et al. Device-related infection in de novo transvenous implantable cardioverter-defibrillator Medicare patients. Heart Rhythm. 2021;18(8):1301-1309.

Publication types

LinkOut - more resources