. 2022 May;31(5):1015-1025.
doi: 10.1016/j.jse.2021.12.030. Epub 2022 Jan 26.

Elbow hemiarthroplasty for acute distal humeral fractures and their sequelae: medium- and long-term follow-up of 41 cases

Affiliations

Elbow hemiarthroplasty for acute distal humeral fractures and their sequelae: medium- and long-term follow-up of 41 cases

Andrea Celli et al. J Shoulder Elbow Surg. 2022 May.

Abstract

Background: The earliest distal humeral hemiarthroplasty (or elbow hemiarthroplasty [EHA]) implants, which date back to the late 1940s, were performed in patients with severe elbow joint injuries as an alternative to arthrodesis. After some clinical reports and case studies with a short follow-up, published in the 1990s, a new "anatomically convertible" EHA model was introduced in 2005 and became a common surgical option to treat complex elbow fractures and their sequelae. We describe the mid- and long-term outcomes of EHA performed to treat acute intra-articular fractures or their sequelae.

Methods: From 2006 to 2017, 51 patients underwent EHA for acute intra-articular fractures or their sequelae. A total number of 41 patients (80.5% female) with a minimum follow-up of 2 years, 24 with acute lesions and 17 with sequelae, were identified retrospectively. Clinical evaluation was according to the Disabilities of the Arm, Shoulder, and Hand (DASH) score (subjective), and the Oxford Elbow Score (OES) and Mayo Elbow Performance Score (MEPS) (objective). Radiographic follow-up was with standard radiographs.

Results: Mean follow-up was 92.2 months (range, 24-151). Mean patient age at surgery was 62.8 years (range, 45-81). The mean MEPS was 87.1 points, with excellent results in 26 cases, good results in 9 cases, fair in 2, and poor results in 4. The mean DASH score was 15.9 and the mean OES was 40.5, with satisfactory results in 30 cases. Twenty patients experienced complications and 2 required revision surgery.

Discussion: EHA is a valuable surgical option in selected patients with comminuted distal humeral joint fractures that cannot be reconstructed with stable fixation and in those with malunion of the articular surface of the humerus. EHA offers potential advantages, especially in active elderly patients and in those aged less than 70 years. It is essential to achieve joint stability, restoring medial and lateral ligament function besides the integrity of the coronoid process. An intact olecranon surface without signs of degenerative changes is also critical for EHA success.

Conclusion: Our mid- and long-term experience with EHA is favorable, with a high proportion of satisfactory results and long survival rates for both lesion types. In selected patients with acute and post-traumatic injuries, EHA is a valuable surgical option.

Keywords: Elbow articular fracture; distal humeral hemiarthroplasty.