Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2022 Sep;67(3):194-211.
doi: 10.1111/adj.12900. Epub 2022 Feb 17.

Comparative analysis between extra-short implants (≤6 mm) and 6 mm-longer implants: a meta-analysis of randomized controlled trial

Affiliations
Free article
Review

Comparative analysis between extra-short implants (≤6 mm) and 6 mm-longer implants: a meta-analysis of randomized controlled trial

Gvo Fernandes et al. Aust Dent J. 2022 Sep.
Free article

Abstract

The goal of this systematic study was to compare the survival rate (SR), marginal bone loss (MBL) and clinical complications between extra-short implants (≤6 mm) and 6-mm-longer implants in randomized clinical trials. A systematic electronic and manual search was performed using the PubMed, Web of Science, Scopus and DOAJ databases. A meta-analysis was conducted to compare the SR and MBL between both groups. We have selected 17 studies out of 1016 articles for qualitative and quantitative analysis. The data from 956 patients and 1779 implants were used with an overall mean clinical follow-up of 3.88 years ranging from 1 to 8 years. Overall, the SR of extra-short implants (93.12%) was lower than the observed in 6-mm-longer implants (95.98%); however, there was no statistical significance on these findings (P > 0.10). MBL analysis showed that extra-short implants and the 6-mm-longer group presented an average of -0.71 and -0.92 mm after 1-year respectively. Three years follow-up showed MBL of -0.42 mm (≤6 mm) and -0.43 mm (>6 mm); 5 years follow-up showed an MBL of -0.69 mm (≤6 mm) and -0.46 mm (>6 mm); and after 8 years of follow-up, it was found an MBL of -1.58 mm (≤6 mm) and -2.46 mm (>6 mm). Within the limitation of this study, the results indicated that SR of extra-short implants was similar to 6-mm-longer implants. In contrast, MBL and the presence of clinical complications were observed at a lessened rate on extra-short implants.

Keywords: Bone augmentation; dental implants; extra-short implants; sinus lift.

PubMed Disclaimer

References

REFERENCES

    1. Sargozaie N, Moeintaghavi A, Shojaie H. Comparing the quality of life of patients requesting dental implants before and after implant. Open Dent J 2017;11:485-491.
    1. Chappuis V, Araújo MG, Buser D. Clinical relevance of dimensional bone and soft tissue alterations post-extraction in esthetic sites. Periodontol 2000;2017:73-83.
    1. Schropp L, Kostopoulos L, Wenzel A. Bone healing following immediate versus delayed placement of titanium implants into extraction sockets: a prospective clinical study. Int J Oral Maxillofac Implants 2003;18:189-199.
    1. Pietrokovski J, Massler M. Alveolar ridge resorption following tooth extraction. J Prosthet Dent 1967;17:21-27.
    1. Johnson K. A study of the dimensional changes occurring in the maxilla following tooth extraction. Aust Dent J 1969;14:241-244.

MeSH terms

Substances