Personal computer programs to assist with self-monitoring of blood glucose and self-adjustment of insulin dosage
- PMID: 3512210
- DOI: 10.2337/diacare.9.1.61
Personal computer programs to assist with self-monitoring of blood glucose and self-adjustment of insulin dosage
Abstract
We have developed computer programs in compiled BASIC for the IBM-PC and compatible microcomputers for use by physicians, paramedical personnel, and/or patients to assist with self-monitoring of blood glucose (SMBG) and self-adjustment of insulin dosage. The programs can potentially assist with patient education and motivation, and provide: a customized "electronic notebook" for storage and retrieval of information on blood glucose, insulin dosage, hypoglycemic reactions, urinary ketones, diet, activity, weight, illness, apparent explanations for hypoglycemic reactions or glucose values outside target ranges, and comments; graphic displays of glucose and insulin versus date, and of a "glucose profile" versus time of day or versus day of the week; simple and detailed statistical analyses; a legible summary of data; a facility to permit the physician to prepare a "customized treatment plan" for each patient, involving a choice of six regimens, target levels for each of eight time periods, four supplement tables (when well or sick, before meals, or at bedtime), rules to reduce insulin in response to hypoglycemic reactions or documented hypoglycemia, rules to increase routine insulin doses in response to persistent unexplained hyperglycemia, and rules when the patient should call the physician; suggestions regarding compensatory supplements and adjustments of routine insulin dosage; explanations why various insulin dosages should or should not be altered, and why various glucose values should be tested; comparisons of the insulin dosage administered by the patient and the recommendations of the program, together with explanations for discrepancies offered by the patient, to help evaluate compliance. The program is "user-friendly," easy to learn, and easy to use.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
The evaluation of a pocket computer as an aid to insulin dose determination by patients.Diabetes Care. 1985 Mar-Apr;8(2):172-6. doi: 10.2337/diacare.8.2.172. Diabetes Care. 1985. PMID: 3838930
-
Will computers replace or complement the diabetes educator?Med J Aust. 1992 Oct 5;157(7):489-91. doi: 10.5694/j.1326-5377.1992.tb137317.x. Med J Aust. 1992. PMID: 1406401
-
Frequent insulin dosage adjustments based on glucose readings alone are sufficient for a safe and effective therapy.J Diabetes Complications. 2012 May-Jun;26(3):230-6. doi: 10.1016/j.jdiacomp.2012.03.012. Epub 2012 Apr 20. J Diabetes Complications. 2012. PMID: 22521317 Clinical Trial.
-
Repaglinide : a pharmacoeconomic review of its use in type 2 diabetes mellitus.Pharmacoeconomics. 2004;22(6):389-411. doi: 10.2165/00019053-200422060-00005. Pharmacoeconomics. 2004. PMID: 15099124 Review.
-
Self-monitoring of blood glucose is associated with problem-solving skills in hyperglycemia and hypoglycemia.Diabetes Educ. 2012 Mar-Apr;38(2):207-18. doi: 10.1177/0145721712440331. Diabetes Educ. 2012. PMID: 22454405 Review.
Cited by
-
Display of glucose distributions by date, time of day, and day of week: new and improved methods.J Diabetes Sci Technol. 2009 Nov 1;3(6):1388-94. doi: 10.1177/193229680900300619. J Diabetes Sci Technol. 2009. PMID: 20144393 Free PMC article.
-
Twelve-Month Follow-up from a Randomized Controlled Trial of Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents with Type 1 Diabetes Using the MiniMed™ 780G Advanced Hybrid Closed-Loop System.Diabetes Technol Ther. 2024 Mar;26(S3):76-83. doi: 10.1089/dia.2023.0429. Diabetes Technol Ther. 2024. PMID: 38377327 Free PMC article. Clinical Trial.
-
Optimizing display, analysis, interpretation and utility of self-monitoring of blood glucose (SMBG) data for management of patients with diabetes.J Diabetes Sci Technol. 2007 Jan;1(1):62-71. doi: 10.1177/193229680700100111. J Diabetes Sci Technol. 2007. PMID: 19888382 Free PMC article.
-