Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Feb 5;13(1):23.
doi: 10.1186/s13244-022-01155-1.

Statement of the Italian Association of Medical Physics (AIFM) task group on radiation dose monitoring systems

Collaborators, Affiliations

Statement of the Italian Association of Medical Physics (AIFM) task group on radiation dose monitoring systems

Francesco Ria et al. Insights Imaging. .

Abstract

The evaluation of radiation burden in vivo is crucial in modern radiology as stated also in the European Directive 2013/59/Euratom-Basic Safety Standard. Although radiation dose monitoring can impact the justification and optimization of radiological procedure, as well as effective patient communication, standardization of radiation monitoring software is far to be achieved. Toward this goal, the Italian Association of Medical Physics (AIFM) published a report describing the state of the art and standard guidelines in radiation dose monitoring system quality assurance. This article reports the AIFM statement about radiation dose monitoring systems (RDMSs) summarizing the different critical points of the systems related to Medical Physicist Expert (MPE) activities before, during, and after their clinical implementation. In particular, the article describes the general aspects of radiation dose data management, radiation dose monitoring systems, data integrity, and data responsibilities. Furthermore, the acceptance tests that need to be implemented and the most relevant dosimetric data for each radiological modalities are reported under the MPE responsibility.

Keywords: Dose monitoring system; Quality assurance; Radiation dose; Statement.

PubMed Disclaimer

Conflict of interest statement

None of the authors of this paper has a financial or personal relationship with other people or organizations that could inappropriately influence or bias the content of the paper.

References

    1. Samei E, Järvinen H, Kortesniemi M, et al. Medical imaging dose optimisation from ground up: expert opinion of an international summit. J Radiol Prot. 2018;38(3):967–989. doi: 10.1088/1361-6498/aac575. - DOI - PubMed
    1. Vañó E, Miller DL, Martin CJ, et al. ICRP publication 135: diagnostic reference levels in medical imaging. Ann ICRP. 2017;46(1):1–144. doi: 10.1177/0146645317717209. - DOI - PubMed
    1. Morin RL, Coombs LP, Chatfield MB. ACR dose index registry. J Am Coll Radiol. 2011;8(4):288–291. doi: 10.1016/j.jacr.2010.12.022. - DOI - PubMed
    1. European Parliament. Council Directive 2013/59/Euratom of 5 December 2013. Off J Eur Commun L13. 2014;(December 2003).
    1. Torresin A, Evans S, Lizio D, Pierotti L, Stasi M, Salerno S. Practical recommendations for the application of DE 59/2013. Radiol Med. 2019;124(8):721–727. doi: 10.1007/s11547-019-01031-x. - DOI - PubMed

LinkOut - more resources