. 2022 Oct;37(4):717-724.
doi: 10.1007/s12928-022-00837-3. Epub 2022 Feb 7.

Late expansion of mechanically expanding transcatheter aortic valves

Affiliations

Late expansion of mechanically expanding transcatheter aortic valves

Yusuke Kobari et al. Cardiovasc Interv Ther. 2022 Oct.

Abstract

Several studies have demonstrated better hemodynamic stability of mechanically expanding valves following transcatheter aortic valve replacement (TAVR). This study aims to assess the expansion or recoil of transcatheter aortic valves using multidetector computed tomography (MDCT). This was a retrospective study. Among 873 patients who underwent TAVR with balloon-expandable (SAPIEN 3) or mechanically expanding valves (LOTUS) at Keio University Hospital between 2013 and 2020, those who underwent serial MDCT and echocardiographic assessment (pre-procedure, discharge, 6 months, 1 year, and 2 years post-TAVR) as our hospital protocol were included in this analysis (N = 30; LOTUS = 12; SAPIEN 3 = 18). The pre- and post-procedural echocardiographic data and the valve expansion rate evaluated by MDCT were compared between the groups. In LOTUS valves, late-phase expansion was observed on computed tomography (mean expansion rate, 83.8% at discharge and 86.8%, 2 years postoperative, p < 0.001), and a gradual increase in the aortic valve area was observed on echocardiography (aortic valve area: 1.45 cm2 at discharge and 1.51 cm2, 2 years postoperative, p = 0.01). Conversely, in SAPIEN 3, valve expansion was not seen in the late phase (mean expansion rate, 84.5% at discharge and 83.8%, 2 years postoperative) with a decrease in the aortic valve area (1.41 cm2 at discharge and 1.37 cm2, 2 years postoperative, p = 0.04). The expansion of the middle portion of the LOTUS valves was attributed to the increase in the aortic valve area. In conclusion, this study demonstrated the greater late-phase expansion and better valve performance of mechanically expanding valves.

Keywords: Aortic valve replacement; Multidetector computed tomography; Transcatheter aortic valve replacement.

PubMed Disclaimer

References

    1. Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med. 2019;380:1695–705. - DOI
    1. Popma JJ, Michael Deeb G, Yakubov SJ, Mumtaz M, Gada H, O’Hair D, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med. 2019;380:1706–15. - DOI
    1. Reardon MJ, Feldman TE, Meduri CU, Makkar RR, O’Hair D, Linke A, et al. Two-year outcomes after transcatheter aortic valve replacement with mechanical vs self-expanding valves: the REPRISE III randomized clinical trial. JAMA Cardiol. 2019;4:223–9. - DOI
    1. Asch FM, Vannan MA, Singh S, Khandheria B, Little SH, Allocco DJ, et al. Hemodynamic and echocardiographic comparison of the lotus and corevalve transcatheter aortic valves in patients with high and extreme surgical risk: an analysis from the REPRISE III randomized controlled trial. Circulation. 2018;137:2557–67. - DOI
    1. Willson AB, Webb JG, Gurvitch R, Wood DA, Toggweiler S, Binder R, et al. Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography. JACC Cardiovasc Interv. 2012;5:525–32. - DOI

LinkOut - more resources