Cuffless Blood Pressure Devices
- PMID: 35136906
- PMCID: PMC9088838
- DOI: 10.1093/ajh/hpac017
Cuffless Blood Pressure Devices
Abstract
Hypertension is associated with more end-organ damage, cardiovascular events, and disability-adjusted life years lost in the United States compared with all other modifiable risk factors. Several guidelines and scientific statements now endorse the use of out-of-office blood pressure (BP) monitoring with ambulatory BP monitoring or home BP monitoring to confirm or exclude hypertension status based on office BP measurement. Current ambulatory or home BP monitoring devices have been reliant on the placement of a BP cuff, typically on the upper arm, to measure BP. There are numerous limitations to this approach. Cuff-based BP may not be well-tolerated for repeated measurements as is utilized with ambulatory BP monitoring. Furthermore, improper technique, including incorrect cuff placement or use of the wrong cuff size, may lead to erroneous readings, affecting diagnosis and management of hypertension. Compared with devices that utilize a cuff, cuffless BP devices may overcome challenges related to technique, tolerability, and overall utility in the outpatient setting. However, cuffless devices have several potential limitations that limit its routine use for the diagnosis and management of hypertension. The review discusses the different approaches for determining BP using various cuffless devices including engineering aspects of cuffless device technologies, validation protocols to test accuracy of cuffless devices, potential barriers to widespread implementation, and future areas of research. This review is intended for the clinicians who utilize out-of-office BP monitoring for the diagnosis and management of hypertension.
Keywords: ambulatory blood pressure monitoring; blood pressure; blood pressure determination; blood pressure monitors; hypertension.
© The Author(s) 2022. Published by Oxford University Press on behalf of American Journal of Hypertension, Ltd. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
References
-
- Muntner P, Shimbo D, Carey RM, Charleston JB, Gaillard T, Misra S, Myers MG, Ogedegbe G, Schwartz JE, Townsend RR, Urbina EM, Viera AJ, White WB, Wright JT Jr. Measurement of blood pressure in humans: a scientific statement from the American Heart Association. Hypertension 2019; 73:e35–e66. - PMC - PubMed
-
- US Preventive Services Task Force. Screening for hypertension in adults: US Preventive Services Task Force Reaffirmation Recommendation Statement. JAMA 2021; 325(16):1650–1656. - PubMed
-
- Sprafka JM, Strickland D, Gómez-Marín O, Prineas RJ. The effect of cuff size on blood pressure measurement in adults. Epidemiology 1991; 2:214–216. - PubMed