Multicenter Performance Evaluation of MALDI-TOF MS for Rapid Detection of Carbapenemase Activity in Enterobacterales: The Future of Networking Data Analysis With Online Software

Affiliations

Multicenter Performance Evaluation of MALDI-TOF MS for Rapid Detection of Carbapenemase Activity in Enterobacterales: The Future of Networking Data Analysis With Online Software

Eva Gato et al. Front Microbiol. .

Abstract

In this study, we evaluate the performance of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for rapid detection of carbapenemase activity in Enterobacterales in clinical microbiology laboratories during a multicenter networking validation study. The study was divided into three different stages: "software design," "intercenter evaluation," and "clinical validation." First, a standardized procedure with an online software for data analysis was designed. Carbapenem resistance was detected by measuring imipenem hydrolysis and the results were automatically interpreted using the Clover MS data analysis software (Clover BioSoft, Spain). Second, a series of 74 genotypically characterized Enterobacterales (46 carbapenemase-producers and 28 non carbapenemase-producers) were analyzed in 8 international centers to ensure the reproducibility of the method. Finally, the methodology was evaluated independently in all centers during a 2-month period and results were compared with the reference standard for carbapenemase detection used in each center. The overall agreement rate relative to the reference method for carbapenemase resistance detection in clinical samples was 92.5%. The sensitivity was 93.9% and the specificity, 100%. Results were obtained within 60 min and accuracy ranged from 83.3 to 100% among the different centers. Further, our results demonstrate that MALDI-TOF MS is an outstanding tool for rapid detection of carbapenemase activity in Enterobacterales in clinical microbiology laboratories. The use of a simple in-house procedure with online software allows routine screening of carbapenemases in diagnostics, thereby facilitating early and appropriate antimicrobial therapy.

Keywords: MALDI-TOF MS; carbapenemases enzymes; clinical microbiology; imipenem; resistance detection.

PubMed Disclaimer

Conflict of interest statement

MArr, JJ, GM, and LM were employed by company Clover BioSoft. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Figures

FIGURE 1
FIGURE 1
Imipenem spectra. The hydrolyzed imipenem spectrum, in the first picture, represents no visible mass peaks for imipenem and only the internal standard, reserpine, is observed at 607 m/z. The later spectrum corresponds to imipenem, with the mass peaks at 300 and 489 m/z and the internal standard at 607 m/z.

References

    1. Anantharajah A., Tossens B., Olive N., Kabamba-Mukadi B., Rodriguez-Villalobos H., Verroken A. (2019). Performance evaluation of the MBT STAR§ -Carba IVD assay for the detection of carbapenemases With MALDI-TOF MS. Front. Microbiol. 10:1413. 10.3389/fmicb.2019.01413 - DOI - PMC - PubMed
    1. Brackmann M., Leib S. L., Tonolla M., Schürch N., Wittwer M. (2020). Antimicrobial resistance classification using MALDI-TOF-MS is not that easy: lessons from vancomycin-resistant Enterococcus faecium. Clin. Microbiol. Infect. 26 391–393. 10.1016/j.cmi.2019.10.027 - DOI - PubMed
    1. Burckhardt I., Zimmermann S. (2011). Using matrix-assisted laser desorption ionization–time of flight mass spectrometry to detect carbapenem resistance within 1 to 2.5 hours. J. Clin. Microbiol. 49 3321–3324. 10.1128/JCM.00287-11 - DOI - PMC - PubMed
    1. Carvalhaes C. G., Ramos A. C., Oliveira L. C. G., Juliano M. A., Gales A. C. (2018). Rapid detection of ceftazidime/avibactam resistance by MALDI-TOF MS. J. Antimicrob. Chemother. 73 2579–2582. 10.1093/jac/dky196 - DOI - PubMed
    1. Clark A. E., Kaleta E. J., Arora A., Wolk D. M. (2013). Matrix-assisted laser desorption ionization-time of flight mass spectrometry: a fundamental shift in the routine practice of clinical microbiology. Clin. Microbiol. Rev. 26 547–603. 10.1128/CMR.00072-12 - DOI - PMC - PubMed