. 2022 Jan 24;11(3):322.
doi: 10.3390/foods11030322.

A Review of Isothermal Amplification Methods and Food-Origin Inhibitors against Detecting Food-Borne Pathogens

Affiliations
Review

A Review of Isothermal Amplification Methods and Food-Origin Inhibitors against Detecting Food-Borne Pathogens

Ye-Ji Moon et al. Foods. .

Abstract

The isothermal amplification method, a molecular-based diagnostic technology, such as loop-mediated isothermal amplification (LAMP) and recombinase polymerase amplification (RPA), is widely used as an alternative to the time-consuming and labor-intensive culture-based detection method. However, food matrices or other compounds can inhibit molecular-based diagnostic technologies, causing reduced detection efficiencies, and false-negative results. These inhibitors originating from food are polysaccharides and polyphenolic compounds in berries, seafood, and vegetables. Additionally, magnesium ions needed for amplification reactions can also inhibit molecular-based diagnostics. The successful removal of inhibitors originating from food and molecular amplification reaction is therefore proposed to enhance the efficiency of molecular-based diagnostics and allow accurate detection of food-borne pathogens. Among molecular-based diagnostics, PCR inhibitors have been reported. Nevertheless, reports on the mechanism and removal of isothermal amplification method inhibitors are insufficient. Therefore, this review describes inhibitors originating from food and some compounds inhibiting the detection of food-borne pathogens during isothermal amplification.

Keywords: bacteria; detection method; food metrix; inhibition; molecular amplification.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Schematic diagram of isothermal amplification techniques.

Similar articles

Cited by

References

    1. Osaili T.M., Hasan F., Dhanasekaran D.K., Obaid R.S., Al-Nabulsi A.A., Ayyash M., Karam L., Savvaidis I.N., Holley R. Effect of active essential oils added to chicken tawook on the behaviour of Listeria monocytogenes, Salmonella spp. and Escherichia coli O157: H7 during storage. Int. J. Food Microbiol. 2021;337:108947. doi: 10.1016/j.ijfoodmicro.2020.108947. - DOI - PubMed
    1. Chai C., Oh S.W. Electrochemical impedimetric biosensors for food safety. Food Sci. Biotechnol. 2020;29:879–887. doi: 10.1007/s10068-020-00776-w. - DOI - PMC - PubMed
    1. Kim J.H., Oh S.W. Rapid and sensitive detection of E. coli O157: H7 and S. Typhimurium in iceberg lettuce and cabbage using filtration, DNA concentration, and qPCR without enrichment. Food Chem. 2020;327:127036. doi: 10.1016/j.foodchem.2020.127036. - DOI - PubMed
    1. Rajapaksha P., Elbourne A., Gangadoo S., Brown R., Cozzolino D., Chapman J. A review of methods for the detection of pathogenic microorganisms. Analyst. 2019;144:396–411. doi: 10.1039/C8AN01488D. - DOI - PubMed
    1. Wang Y., Qi W., Wang L., Lin J., Liu Y. Magnetic Bead Chain-Based Continuous-Flow DNA Extraction for Microfluidic PCR Detection of Salmonella. Micromachines. 2021;12:384. doi: 10.3390/mi12040384. - DOI - PMC - PubMed