Coronary CT Angiography with Photon-counting CT: First-In-Human Results
- PMID: 35166583
- DOI: 10.1148/radiol.211780
Coronary CT Angiography with Photon-counting CT: First-In-Human Results
Abstract
Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.
Comment in
-
Overcoming a Technological Hurdle: Coronary CT Angiography with Photon-counting CT.Radiology. 2022 May;303(2):314-316. doi: 10.1148/radiol.212943. Epub 2022 Feb 15. Radiology. 2022. PMID: 35166592 No abstract available.
Similar articles
-
First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography.Invest Radiol. 2022 Apr 1;57(4):212-221. doi: 10.1097/RLI.0000000000000835. Invest Radiol. 2022. PMID: 34711766 Free PMC article.
-
Thin slice photon-counting CT coronary angiography compared to conventional CT: Objective image quality and clinical radiation dose assessment.Med Phys. 2024 Apr;51(4):2924-2932. doi: 10.1002/mp.16992. Epub 2024 Feb 15. Med Phys. 2024. PMID: 38358113
-
Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising.Med Phys. 2023 Jul;50(7):4173-4181. doi: 10.1002/mp.16415. Epub 2023 Apr 17. Med Phys. 2023. PMID: 37069830 Free PMC article.
-
Dual-Source Photon-Counting Computed Tomography-Part I: Clinical Overview of Cardiac CT and Coronary CT Angiography Applications.J Clin Med. 2023 May 23;12(11):3627. doi: 10.3390/jcm12113627. J Clin Med. 2023. PMID: 37297822 Free PMC article. Review.
-
Photon-Counting CT: Technology, Current and Potential Future Clinical Applications, and Overview of Approved Systems and Those in Various Stages of Research and Development.Radiology. 2025 Mar;314(3):e240662. doi: 10.1148/radiol.240662. Radiology. 2025. PMID: 40067107 Review.
Cited by
-
Computed Tomography Angiography Identified High-Risk Coronary Plaques: From Diagnosis to Prognosis and Future Management.Diagnostics (Basel). 2024 Aug 1;14(15):1671. doi: 10.3390/diagnostics14151671. Diagnostics (Basel). 2024. PMID: 39125547 Free PMC article. Review.
-
High-pitch, high temporal resolution, multi-energy cardiac imaging on a dual-source photon-counting-detector CT.Med Phys. 2023 Mar;50(3):1428-1435. doi: 10.1002/mp.16124. Epub 2022 Dec 17. Med Phys. 2023. PMID: 36427356 Free PMC article.
-
Non-invasive pediatric cardiac imaging-current status and further perspectives.Mol Cell Pediatr. 2022 Dec 28;9(1):21. doi: 10.1186/s40348-022-00153-z. Mol Cell Pediatr. 2022. PMID: 36575291 Free PMC article. Review.
-
Coronary Computed Tomography vs. Cardiac Magnetic Resonance Imaging in the Evaluation of Coronary Artery Disease.Diagnostics (Basel). 2022 Dec 30;13(1):125. doi: 10.3390/diagnostics13010125. Diagnostics (Basel). 2022. PMID: 36611417 Free PMC article. Review.
-
Cardiac CT in CRT as a Singular Imaging Modality for Diagnosis and Patient-Tailored Management.J Clin Med. 2023 Sep 26;12(19):6212. doi: 10.3390/jcm12196212. J Clin Med. 2023. PMID: 37834855 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources