Differential clock comparisons with a multiplexed optical lattice clock
- PMID: 35173344
- DOI: 10.1038/s41586-021-04344-y
Differential clock comparisons with a multiplexed optical lattice clock
Abstract
Rapid progress in optical atomic clock performance has advanced the frontiers of timekeeping, metrology and quantum science1-3. Despite considerable efforts, the instabilities of most optical clocks remain limited by the local oscillator rather than the atoms themselves4,5. Here we implement a 'multiplexed' one-dimensional optical lattice clock, in which spatially resolved strontium atom ensembles are trapped in the same optical lattice, interrogated simultaneously by a shared clock laser and read-out in parallel. In synchronous Ramsey interrogations of ensemble pairs we observe atom-atom coherence times of 26 s, a 270-fold improvement over the measured atom-laser coherence time, demonstrate a relative instability of [Formula: see text] (where τ is the averaging time) and reach a relative statistical uncertainty of 8.9 × 10-20 after 3.3 h of averaging. These results demonstrate that applications involving optical clock comparisons need not be limited by the instability of the local oscillator. We further realize a miniaturized clock network consisting of 6 atomic ensembles and 15 simultaneous pairwise comparisons with relative instabilities below [Formula: see text], and prepare spatially resolved, heterogeneous ensemble pairs of all four stable strontium isotopes. These results pave the way for multiplexed precision isotope shift measurements, spatially resolved characterization of limiting clock systematics, the development of clock-based gravitational wave and dark matter detectors6-12 and new tests of relativity in the lab13-16.
© 2022. The Author(s), under exclusive licence to Springer Nature Limited.
Comment in
-
Atomic clouds stabilized to measure dilation of time.Nature. 2022 Feb;602(7897):391-392. doi: 10.1038/d41586-022-00379-x. Nature. 2022. PMID: 35173336 No abstract available.
References
-
- Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E. & Schmidt, P. O. Optical atomic clocks. Rev. Mod. Phys. 87, 637–701 (2015). - DOI
-
- Schioppo, M. et al. Ultrastable optical clock with two cold-atom ensembles. Nat. Photon. 11, 48–52 (2017). - DOI
-
- Oelker, E. et al. Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks. Nat. Photon. 13, 714–719 (2019). - DOI
Publication types
LinkOut - more resources
Full Text Sources
Miscellaneous