. 2022 Nov-Dec;12(6):533-538.
doi: 10.1016/j.prro.2022.02.004. Epub 2022 Feb 19.

Development of Simplified Auto-Segmentable Functional Cardiac Atlas

Affiliations

Development of Simplified Auto-Segmentable Functional Cardiac Atlas

Pierre Loap et al. Pract Radiat Oncol. 2022 Nov-Dec.

Abstract

Purpose: There is increasing evidence that radiation doses to cardiac substructures are associated with cardiac adverse events. Manual delineation of cardiac substructures is time-consuming, and auto-segmentation of cardiac substructure atlases has consequently been evaluated. However, proper automatic delineation of small substructures, such as the left anterior descending coronary artery, is challenging, and auto-segmentation of cardiac conduction system substructures has never been evaluated, despite multiple reports of radiation-induced arrhythmia after thoracic irradiations. The aim of this study was to propose and evaluate a simplified auto-segmentable functional cardiac atlas.

Methods and materials: We created a cardiac substructure atlas based on 20 computed tomography scans from patients with breast cancer comprising the 4 cardiac cavities, a high-risk cardiac zone as a left anterior descending coronary artery surrogate, and the 2 cardiac conduction nodes. Automatic delineation of this atlas by an atlas-based auto-segmentation algorithm was evaluated on a validation data set, consisting of 20 additional computed tomography scans. Dice similarity coefficients were used to evaluate the concordance level between the manual and the automatic contours; a dosimetric comparison between mean and maximum doses to the manual and to the auto-segmented substructures was additionally performed, based on intensity modulated radiation therapy treatment plans of the patients of the validation set.

Results: Average dice similarity coefficient values were 0.78 for the 4 cardiac cavities, 0.65 for the high-risk cardiac zones, 0.56 for the sinoatrial node, and 0.15 for the atrioventricular node. Compared with manual contours, auto-segmented substructures were slightly smaller but the dosimetric parameters were similar.

Conclusions: We proposed a simplified functional cardiac atlas that included the cardiac conduction system and circumvented coronary delineation difficulties by using a surrogate high-risk cardiac zone. Most cardiac substructures were associated with acceptable atlas-based auto-segmentation properties. Such an atlas could be used for epidemiologic studies and for clinical practice.

PubMed Disclaimer

MeSH terms

LinkOut - more resources