Radiographic evaluation of the margins of clinically acceptable metal-ceramic crowns
- PMID: 35202367
- DOI: 10.47391/JPMA.AKU-08
Radiographic evaluation of the margins of clinically acceptable metal-ceramic crowns
Abstract
Objective: To radiographically evaluate the proximal marginal fit of the clinically acceptable metal-ceramic crowns.
Methods: The prospective study was conducted at the dental clinics of Aga Khan University, Karachi, from July to December 2018, and comprised metal-ceramic crowns that were evaluated prior to the cementation. Clinical examinations were conducted by seating the crown on the tooth preparation and visual assessment was done using sharp explorer along the margins. Clinically acceptable crowns were then evaluated on the bite-wing radiograph. Any horizontal or vertical inaccuracy of >0.5mm at the proximal margins was recorded as 'discrepancy'. Data was analysed using SPSS 22.
Results: Of the 230 interproximal margins of 115 crowns evaluated, 113(49.1%) sites had marginal discrepancies; 44(19.1%) horizontal discrepancies, 58(25.2%) vertical discrepancies, and 11(4.8%) having both horizontal and vertical discrepancies. Horizontal crown margin discrepancies were most associated with the mesial site of the maxillary crowns, while vertical discrepancies were commonly associated with the distal aspect of all crowns (p<0.050).
Conclusions: Almost half of the crowns that were considered clinically acceptable had some vertical or horizontal marginal discrepancy on radiographic evaluation.
Keywords: Crown, Margins, Dental radiography, Metal ceramic crowns.
Similar articles
-
Evaluating ceramic crown margins with digital radiography.J Prosthet Dent. 2018 May;119(5):777-782. doi: 10.1016/j.prosdent.2017.07.020. Epub 2017 Sep 29. J Prosthet Dent. 2018. PMID: 28969920
-
A comparison of three-dimensional marginal adaptation among three all-ceramic crown systems.Shanghai Kou Qiang Yi Xue. 2011 Oct;20(5):494-9. Shanghai Kou Qiang Yi Xue. 2011. PMID: 22109367
-
Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems.J Prosthet Dent. 2005 Apr;93(4):346-55. doi: 10.1016/j.prosdent.2005.02.003. J Prosthet Dent. 2005. PMID: 15798685
-
Marginal adaptation of implant-supported metal-ceramic crowns fabricated with gold cylinders.J Prosthodont. 1998 Jun;7(2):100-5. doi: 10.1111/j.1532-849x.1998.tb00187.x. J Prosthodont. 1998. PMID: 9743663
-
Gingival margins for crowns: a review and discussion. Part II: Discrepancies and configurations.J Prosthet Dent. 1990 Dec;64(6):636-42. doi: 10.1016/0022-3913(90)90286-l. J Prosthet Dent. 1990. PMID: 2079668 Review.
MeSH terms
LinkOut - more resources
Miscellaneous