Impact of the introduction of a low-cost uterine balloon tamponade (ESM-UBT) device for managing severe postpartum hemorrhage in India: A comparative before-and-after study

Affiliations

Impact of the introduction of a low-cost uterine balloon tamponade (ESM-UBT) device for managing severe postpartum hemorrhage in India: A comparative before-and-after study

Thomas F Burke et al. Int J Gynaecol Obstet. 2022 Nov.

Abstract

Objective: To evaluate the impact of introducing a uterine balloon tamponade (ESM-UBT) device for managing severe postpartum hemorrhage (PPH), mainly due to uterine atony, in health facilities in India on the rates of PPH-related maternal death and invasive procedures for PPH control.

Methods: We used a quasi-experimental, difference-in-difference (DID) design to compare changes in the rates of a composite outcome (PPH-related maternal death and/or artery ligation, uterine compression sutures, or hysterectomy) among women delivering in nine intervention facilities compared with those delivering in two control facilities, before and after the introduction of ESM-UBT.

Results: The study sample included 214 123 deliveries (n = 78 509 before ESM-UBT introduction; n = 47 211 during ESM-UBT introduction; and n = 88 403 after ESM-UBT introduction). After introduction of ESM-UBT, there was a significant decline in the rate of the primary composite outcome in intervention facilities (21.0-11.4 per 10 000 deliveries; difference -9.6, 95% confidence interval -14.0 to -5.4). Change in the rate of the primary composite outcome was not significant in control facilities (11.7-17.2 per 10 000 deliveries; difference 5.4, 95% confidence interval -3.9 to 14.9). DID analyses showed there was a significant reduction in the rate of the primary composite outcome in intervention facilities relative to control facilities (adjusted DID estimate -15.0 per 10 000 points, 95% confidence interval -23.3 to -6.8; P = 0.005).

Conclusion: Introduction of the ESM-UBT in health facilities in India was associated with a significant reduction in PPH-related maternal death and/or invasive procedures for PPH control.

Keywords: artery ligation; hysterectomy; maternal death; postpartum hemorrhage; uterine balloon tamponade; uterine compression sutures.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Say L, Chou D, Gemmill A, et al. Global causes of maternal death: a WHO systematic analysis. Lancet Glob Health. 2014;2:e323-e333.
    1. Trends in maternal mortality 2000 to 2017: estimates by WHO, UNICEF, UNFPA, World Bank Group and the United Nations Population Division. World Health Organization; 2019. Licence: CC BY-NC-SA 3.0 IGO.
    1. Bauserman M, Thorsten VR, Nolen TL, et al. Maternal mortality in six low and lower-middle income countries from 2010 to 2018: risk factors and trends. Reprod Health. 2020;17(Suppl 3):173.
    1. Maswime S, Buchmann E. A systematic review of maternal near miss and mortality due to postpartum hemorrhage. Int J Gynaecol Obstet. 2017;137:1-7.
    1. Sheldon WR, Blum J, Vogel JP, Souza JP, Gülmezoglu AM, Winikoff B. WHO multicountry survey on maternal and newborn Health Research network. Postpartum haemorrhage management, risks, and maternal outcomes: findings from the World Health Organization multicountry survey on maternal and newborn health. BJOG. 2014;121(Suppl 1):5-13.

LinkOut - more resources