[Functional rehabilitation after transfemoral amputation : Shaft prosthesis or endo-exo prosthesis?]
- PMID: 35212810
- DOI: 10.1007/s00113-022-01148-1
[Functional rehabilitation after transfemoral amputation : Shaft prosthesis or endo-exo prosthesis?]
Abstract
Background: After transfemoral amputation a prosthesis is required to restore autonomous standing and bipedal locomotion. Attachment of the prosthesis can be achieved either classically via socket suspension with a shaft in the stump or directly via implantation of an intramedullary transcutaneous femoral prosthesis (osseointegrated prosthesis).
Aim: A fully instrumented gait analysis should enable objectification of the anticipated advantages of the EEP with respect to the gait pattern and individual mobility.
Material and methods: In two patients with a unilateral transfemoral amputation a comprehensive gait analysis was carried out prior to and 6 months (patient 1) or 11 and 20 months (patient 2) after switching from a socket prosthesis to an EEP. This was carried out in the Gait Realtime Analysis Interactive Lab (GRAIL), a fully instrumented gait laboratory with virtual reality and enables assessment close to the conditions of daily life.
Results: In both cases the gait analysis confirmed the advantages associated with an EEP for the transmission of force to the prosthesis and the accompanying improvement in gait symmetry.
Zusammenfassung: HINTERGRUND: Nach einer transfemoralen Amputation sind sicheres Stehen und die bipedale Fortbewegung nur noch mithilfe einer Prothese möglich. Diese kann entweder „klassisch“ über einen den Stumpf umfassenden Schaft oder direkt über einen im Knochen verankerten und durch die Haut ausgeleiteten Prothesenstiel (Endo-Exo-Prothese, EEP) angekoppelt werden.
Ziel der arbeit: Eine umfassende Ganganalyse sollte es erlauben, die mit einer EEP antizipierten Vorteile für das Gangbild und die individuelle Mobilität zu objektivieren.
Material und methoden: Bei 2 Patienten wurden jeweils vor und 6 Monate (Patient 1) bzw. 11 und 20 Monate (Patient 2) nach dem Wechsel von einer Schaftprothese auf die EEP umfassende Ganganalysen durchgeführt. Diese erfolgten im Gait Real-Time Analysis Interactive Lab (GRAIL), einem vollinstrumentiertem Ganglabor, das Analysen unter alltagsrelevanten Bedingungen durch die Nutzung von virtueller Realität erlaubt.
Ergebnisse: In beiden Fällen bestätigte die Ganganalyse die mit einer EEP assoziierten Vorteile für die Kraftübertragung auf die Prothese und die damit einhergehende Verbesserung der Gangsymmetrie.
Keywords: Gait analysis; Kinematics; Kinetics; Prostheses and implants; Virtual reality.
© 2022. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.
Similar articles
-
[The endo-exo prosthesis treatment concept : Improvement in quality of life after limb amputation].Unfallchirurg. 2017 May;120(5):371-377. doi: 10.1007/s00113-017-0350-1. Unfallchirurg. 2017. PMID: 28470463 Review. German.
-
[Endo-exo prostheses following limb-amputation].Orthopade. 2015 Jun;44(6):419-25. doi: 10.1007/s00132-015-3117-9. Orthopade. 2015. PMID: 25971241 Clinical Trial. German.
-
Percutaneous Osseointegrated Prostheses for Transfemoral Amputations.Orthopedics. 2018 Mar 1;41(2):75-80. doi: 10.3928/01477447-20180227-03. Orthopedics. 2018. PMID: 29566253
-
Osseointegrated Prosthetic Implants for People With Lower-Limb Amputation: A Health Technology Assessment.Ont Health Technol Assess Ser. 2019 Dec 12;19(7):1-126. eCollection 2019. Ont Health Technol Assess Ser. 2019. PMID: 31911825 Free PMC article.
-
[Connecting adapter for coupling exoprostheses to endoshafts : Demands on orthopedic technicians with respect to planning and application].Unfallchirurg. 2017 May;120(5):378-384. doi: 10.1007/s00113-017-0351-0. Unfallchirurg. 2017. PMID: 28470462 Review. German.
Cited by
-
Impact of topography and added TiN-coating on adult human dermal fibroblasts after seeding on titanium surface in-vitro.J Biomater Appl. 2024 Mar;38(8):905-914. doi: 10.1177/08853282241233194. Epub 2024 Feb 15. J Biomater Appl. 2024. PMID: 38358702 Free PMC article.
References
Literatur
-
- Al Muderis M, Lu W, Li JJ (2017) Osseointegrated prosthetic limb for the treatment of lower limb amputations : experience and outcomes. Unfallchirurg 120:306–311 - DOI
-
- Aschoff HH (2017) Transcutaneous osseointegration (part 2). Unfallchirurg 120:366 - DOI
-
- Aschoff HH (2017) Transcutaneous osseointegration after limb amputation: a review over 27 years. Unfallchirurg 120:278–284 - DOI
-
- Aschoff HH, Clausen A, Tsoumpris K et al (2011) Implantation of the endo-exo femur prosthesis to improve the mobility of amputees. Oper Orthop Traumatol 23:462–472 - DOI
-
- Aschoff HH, Juhnke DL (2016) Endo-exo prostheses : osseointegrated percutaneously channeled implants for rehabilitation after limb amputation. Unfallchirurg 119:421–427 - DOI
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous