Comparison of homogeneous enzyme immunoassay and high-pressure liquid chromatography for the determination of theophylline concentration in serum
- PMID: 352208
- DOI: 10.1164/arrd.1978.117.6.1135
Comparison of homogeneous enzyme immunoassay and high-pressure liquid chromatography for the determination of theophylline concentration in serum
Abstract
A comparison of the new homogeneous enzyme-multiplied immunoassay technique (EMIT, Syva) with a high-pressure liquid chromatographic technique for the determination of theophylline concentration is presented. The accuracy, precision, and specificity of the methods were compared. In addition, 100 samples from 61 pediatric patients receiving theophylline were assayed by both methods. The accuracy, precision, and specificity of the enzyme immunoassay support the use of this method for the quantification of theophylline concentration in clinical specimens. A significant correlation (R = 0.981, P less than 0.001) was found between results generated by enzyme immunoassay and high-pressure liquid chromatography for patient samples. The regression line relating these results had an intercept of 0.22 microgram per ml, a slope of 1.05, and a standard error of the estimate of 1.36 microgram per ml.
Similar articles
-
Comparison of serum theophylline concentrations measured by high pressure liquid chromatography and quantitative enzyme-multiplied immunoassay technique.Ann Allergy. 1979 Feb;42(2):77-9. Ann Allergy. 1979. PMID: 369408
-
Comparison of a high performance liquid chromatographic and an enzyme immunoassay technique for quantitation of theophylline in serum.Ther Drug Monit. 1979;1(1):65-73. doi: 10.1097/00007691-197901000-00007. Ther Drug Monit. 1979. PMID: 399811
-
Comparison of the Seralyzer and EMIT systems for determination of theophylline concentrations.Am J Hosp Pharm. 1986 Jul;43(7):1722-6. Am J Hosp Pharm. 1986. PMID: 3529948
-
Methods of theophylline assay and therapeutic monitoring of this drug.Ann Biol Clin (Paris). 1990;48(5):287-93. Ann Biol Clin (Paris). 1990. PMID: 2195925 Review.
-
Specific methods for theophylline assay in biological samples.Eur J Respir Dis Suppl. 1980;109:45-53. Eur J Respir Dis Suppl. 1980. PMID: 7002578 Review.
Cited by
-
Sustained release theophylline preparations. Practical recommendations for prescribing and therapeutic drug monitoring.Drugs. 1988 Jun;35(6):711-26. doi: 10.2165/00003495-198835060-00006. Drugs. 1988. PMID: 3048977 Review.
-
Enoxacin decreases the clearance of theophylline in man.Br J Clin Pharmacol. 1985 Dec;20(6):583-8. doi: 10.1111/j.1365-2125.1985.tb05115.x. Br J Clin Pharmacol. 1985. PMID: 3867394 Free PMC article.
-
Recent advances in respiratory medicine.Postgrad Med J. 1983 Jan;59(687):1-16. doi: 10.1136/pgmj.59.687.1. Postgrad Med J. 1983. PMID: 6346301 Free PMC article. Review. No abstract available.
-
Fraction of theophylline in sustained-release formulation which is absorbed from the large bowel.Eur J Clin Pharmacol. 1990;38(2):171-3. doi: 10.1007/BF00265979. Eur J Clin Pharmacol. 1990. PMID: 1970960 Clinical Trial.
-
New drugs in respiratory disorders: I.Br Med J (Clin Res Ed). 1983 Mar 12;286(6368):871-5. doi: 10.1136/bmj.286.6368.871. Br Med J (Clin Res Ed). 1983. PMID: 6131723 Free PMC article. Review. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources