Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jun 1;33(4):209-215.
doi: 10.1097/MBC.0000000000001129. Epub 2022 Mar 2.

Evaluation of D-dimer levels measured by different analytical methods in COVID-19 patients

Affiliations

Evaluation of D-dimer levels measured by different analytical methods in COVID-19 patients

Fatma Demet Arslan et al. Blood Coagul Fibrinolysis. .

Abstract

Clinicians experience some challenges due to the lack of standardization of test, although D-dimer is a prognostic marker for COVID-19. We compared the clinical and analytical performances of D-dimer results obtained from different devices, kits and methods in patients with a diagnosis of COVID-19. Thirty-nine patients with a diagnosis of COVID-19 and 24 healthy individuals were included in the study. D-dimer levels were measured with Innovance D-DIMER kit (immunoturbidimetric method) on Sysmex CS-2500 and BCS XP and VIDAS D-Dimer Exclusion II kit (enzyme-linked fluorescence method) on mini VIDAS. The studies of precision, method comparison and clinic performance were performed. The variation coefficients in all systems were within the acceptable imprecision (7.8%). Bias%(12.5%) between BCS XP and Sysmex CS-2500 was lower than the acceptable Bias%(15.5%). Bias% values (19.2% and 33.3%, respectively) between Mini VIDAS with BCS XP and Sysmex CS-2500 were higher than the acceptable Bias%. The correlation coefficients among all systems were 0.89-0.98. For 500 ng/ml FEU, there was almost perfect agreement between BCS XP and Sysmex CS-2500, a moderate agreement between Mini VIDAS and BCS XP and Sysmex CS-2500. The cut-off values for distinguishing between individuals with and withoutCOVID-19 were Mini VIDAS, Sysmex CS-2500 and BCS XP 529, 380 and 390 ng/ml FEU, respectively. The immunoturbidimetric method can be used as an alternative to the enzyme-linked fluorescent method because of satisfactory agreement at the different thresholds proposed for venous thromboembolism. However, it is recommended to follow up COVID-19 with the D-dimer results obtained by the same assay system.

PubMed Disclaimer

References

    1. Thachil J, Longstaff C, Favaloro EJ, Lippi G, Urano T, Kim PY, et al. The need for accurate D-dimer reporting in COVID-19: Communication from the ISTH SSC on fibrinolysis. J Thromb Haemost 2020; 18:2408–2411.
    1. Tang N, Li D, Wang X, Sun Z. Abnormal coagulation parameters are associated with poor prognosis in patients with novel coronavirus pneumonia. J Thromb Haemost 2020; 18:844–847.
    1. Tang N, Bai H, Chen X, Gong J, Li D, Sun Z. Anticoagulant treatment is associated with decreased mortality in severe coronavirus disease 201 9 patients with coagulopathy. J Thromb Haemost 2020; 18:1094–1099.
    1. Zhang L, Yan X, Fan Q, Liu H, Liu X, Liu Z, et al. D-dimer levels on admission to predict in-hospital mortality in patients with Covid-19. J Thromb Haemost 2020; 18:1324–1329.
    1. Leonard-Lorant I, Delabranche X, Severac F, Helms J, Pauzet C, Collange O. Acute pulmonary embolism in COVID-19 patients on CT angiography and relationship to D-dimer levels. Radiology 2020; 296:E189–E191.

Substances