A safe and effective low pressure tourniquet. A prospective evaluation
- PMID: 3525572
- DOI: 10.1302/0301-620X.68B4.3525572
A safe and effective low pressure tourniquet. A prospective evaluation
Abstract
An unusually wide pneumatic tourniquet has recently become available; we provide a simple formula for its use with a low but effective inflation pressure. A prospective, randomised and controlled trial in 600 lower limb and 150 upper limb operations is reported. The wide tourniquet (12.5 cm) was as effective at low pressure as was a conventional tourniquet (9 cm) inflated to significantly higher pressures. Fewer patients suffered from painful paraesthesiae after operation using the broad, low-pressure tourniquet.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical