Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2022 Aug:41:69-75.
doi: 10.1016/j.carrev.2022.01.020. Epub 2022 Jan 25.

Sustained Safety and Efficacy of Magnesium Reabsorbable Scaffold: 2-Year Follow-Up Analysis From First Magmaris Multicenter Italian Registry

Affiliations
Multicenter Study

Sustained Safety and Efficacy of Magnesium Reabsorbable Scaffold: 2-Year Follow-Up Analysis From First Magmaris Multicenter Italian Registry

Stefano Galli et al. Cardiovasc Revasc Med. 2022 Aug.

Abstract

Background: Magnesium Reabsorbable Scaffold (MRS), is the newest reabsorbable technology with low thrombogenicity, short scaffolding time and almost complete resorption at 12-months (95%). Preliminary 12-months data in selected patients has shown that safety and efficacy are comparable with second generation Drug Eluting Stent (DES). Magmaris Multicenter registry showed 1-and 2-years clinical outcome on the first patients suitable for MRS enrolled in 4 Italian centers.

Methods: We evaluated 12- and 24-months clinical results in "real world" experience with Magnesium Reabosrbable Scaffold in terms of Target Lesion Failure (TLF) and scaffold thrombosis (ST). TLF is the primary endpoint and was defined as composite of cardiac mortality, target vessel myocardial infarction (MI), and ischemia-driven target lesion revascularization (ID-TLR). 4P's strategy (Patient/lesion selection, Pre-dilatation, Proper scaffold sizing and Post-dilatation) was strongly recommended. Dual Antiplatelet Therapy (DAPT) has been recommended for 12 months.

Results: Data from 207 patients, including initial experience, have been collected. Patients were 83% male, 20% diabetic and Acute Coronary Syndrome (ACS) in 23%. Lesion type were A-B1 in 54% and B2C in 46%. 4P's strategy was respected in 94%. Procedural success was 98% (2% peri-procedural MI). Compliance at 12-months follow up was 97.6%, TLF rate was 5.4% (including 1 case of myocardial infarction with late scaffold thrombosis (ST), all patients were successfully treated with in-scaffold segment DES implantation). At 24-months compliance was 92.8% (192 patients) and TLF was 7.4%. In the period between 13 and 24 months only 4 patients had TLF (including 1 case of myocardial infarction, all patients were successfully treated with in-scaffold segment DES implantation). None of the patients died for a cardiac reason.

Conclusion: Our 2-years results confirm safety and efficacy showed at 12-months, reinforcing long-term performance with only 2% rate of TLF increase and no ST after 1 year.

Keywords: Magnesium reabsorbable scaffold; NSTEMI, bioresorbable scaffolds; Scaffold thrombosis; Stable angina.