Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021;13(5):6-10.
doi: 10.17691/stm2021.13.5.01. Epub 2021 Oct 29.

Augmentation of Pedicle Screws Using Bone Grafting in Patients with Spinal Osteoporosis

Affiliations

Augmentation of Pedicle Screws Using Bone Grafting in Patients with Spinal Osteoporosis

A E Bokov et al. Sovrem Tekhnologii Med. 2021.

Abstract

The aim of the study was to develop a new method of vertebral augmentation based on autologous and allogeneic bone chips to be used in pedicle screw fixation and to compare this method with the technique based on polymethyl methacrylate (PMMA).

Materials and methods: This prospective non-randomized study included 164 patients with degenerative pathologies or traumatic injuries of the lumbar spine and transitional thoracolumbar segments; 153 of the operated patients were followed up for 18 months. In these patients, radiodensity of the cancellous bone tissue was below 110 HU by the Hounsfield scale. Patients with degenerative spinal disorders underwent pedicle screw fixation using transforaminal interbody fusion; patients with traumatic spinal injuries underwent intermediate pedicle screw fixation, and those with a loss of vertebral body height by >50% underwent anterior fusion.The patients were divided into three groups: in group 1 (n=39), bone tissue augmentation was performed using PMMA; in group 2 (n=21), augmentation was done with bone chips; in group 3 (n=93), no augmentation was performed (control group). The follow-up period was 12 months; cases with fixator breakage or loosening were recorded.

Results: After augmentation with PMMA, 11 cases (28.2%) of fixator destabilization were detected. With bone chips, fixator instability developed in 2 patients (9.5%) only, whereas in patients operated without augmentation, the instability was observed in 43 cases (46.2%). With PMMA augmentation, the incidence rate of fixator destabilization did not significantly differ from that in the control group (p=0.0801), while the use of bone chips resulted in a statistically significant decrease of this index compared to the control group (p=0.0023). A logistic regression analysis confirmed the superiority of the developed method over the PMMA-based vertebral augmentation.

Conclusion: The use of bone chips for vertebral augmentation provides a statistically significant decrease in the incidence of pedicle screw fixator destabilization in the post-operative period. By reducing the risk of proximal loosening and eliminating the risk of bone cement drainage into the spinal canal and vascular bed, the proposed method may become especially effective in patients with impaired bone density.

Keywords: bone cement; low bone density; pedicle screw fixation; pedicle screw instability; polymethyl methacrylate; vertebral augmentation.

PubMed Disclaimer

Conflict of interest statement

Conflicts of interest. There are no conflicts of interest.

Similar articles

References

    1. Li B., Sun C., Zhao C., Yao X., Zhang Y., Duan H., Hao J., Guo X., Fan B., Ning G., Feng S. Epidemiological profile of thoracolumbar fracture (TLF) over a period of 10 years in Tianjin, China. J Spinal Cord Med. 2019;42(2):178–183. doi: 10.1080/10790268.2018.1455018. - DOI - PMC - PubMed
    1. Jensen R.K., Jensen T.S., Koes B., Hartvigsen J. Prevalence of lumbar spinal stenosis in general and clinical populations: a systematic review and meta-analysis. Eur Spine J. 2020;29(9):2143–2163. doi: 10.1007/s00586-020-06339-1. - DOI - PubMed
    1. Wu Z.X., Gong F.T., Liu L., Ma Z.S., Zhang Y., Zhao X., Yang M., Lei W., Sang H.X. A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws. Arch Orthop Trauma Surg. 2012;132(4):471–476. doi: 10.1007/s00402-011-1439-6. - DOI - PubMed
    1. Röllinghoff M., Schlüter-Brust K., Groos D., Sobottke R., Michael J.W., Eysel P., Delank K.S. Mid-range outcomes in 64 consecutive cases of multilevel fusion for degenerative diseases of the lumbar spine. Orthop Rev (Pavia) 2010;2(1):e3. doi: 10.4081/or.2010.e3. - DOI - PMC - PubMed
    1. Zou D., Sun Z., Zhou S., Zhong W., Li W. Hounsfield units value is a better predictor of pedicle screw loosening than the T-score of DXA in patients with lumbar degenerative diseases. Eur Spine J. 2020;29(5):1105–1111. doi: 10.1007/s00586-020-06386-8. - DOI - PubMed

LinkOut - more resources