Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jul-Dec;11(2):261-265.
doi: 10.4103/ams.ams_70_21. Epub 2022 Feb 1.

Evaluation of Serum Metal Ion Levels in Dental Implant Patients: A Prospective Study

Affiliations

Evaluation of Serum Metal Ion Levels in Dental Implant Patients: A Prospective Study

Gayathri Gopi et al. Ann Maxillofac Surg. 2021 Jul-Dec.

Abstract

Introduction: Titanium is the most commonly used bio-inert implant material. Nevertheless, there is a possibility of systemic release of metal ions, which could have clinical implications like implant failure and toxicity. This prospective study focuses on the evaluation of serum metal ion levels in patients receiving dental implants. The aim of the study is to evaluate the release of titanium, aluminium, and vanadium from dental implants by comparing the preoperative and postoperative serum levels of these ions.

Methodology: Serum samples were collected from 30 patients undergoing dental implant placement preoperatively and postoperatively at intervals of 6 weeks, 3, 6, and 12 months. These samples were analyzed for titanium, aluminium, and vanadium levels using Inductively Coupled Plasma Optical Emission Spectrometry. The difference in preoperative and postoperative serum levels was measured and statistically analyzed using the paired t-test.

Results: There was a slight difference in the postoperative levels of titanium and aluminium (2.30 and 4.07 mg/dl) as compared to the preoperative levels (2.28 and 2.30 mg/dl), which was statistically insignificant (P > 0.5). The serum levels of vanadium were too insignificant to be detected by the instrument (<0.0088 mg/dl).

Discussion: Mild increase in the titanium and aluminium levels in blood serum was noted. These metallic ion levels might increase significantly due to which further clinical research with larger sample sizes and a long-term follow-up period is required to evaluate the clinical effects of metallic ion release from dental implants. There is no significant difference in the serum metal ion levels before and after the implant placement, although a little increase is observed in the aluminium ion levels after the implant placement.

Keywords: Aluminium; dental implant; spectrometry; titanium; vanadium.

PubMed Disclaimer

Conflict of interest statement

There are no conflicts of interest.

Similar articles

Cited by

References

    1. Jorge JR, Barão VA, Delben JA, Faverani LP, Queiroz TP, Assunção WG. Titanium in dentistry: Historical development, state of the art and future perspectives. J Indian Prosthodont Soc. 2013;13:71–7. - PMC - PubMed
    1. Carlsson L, Röstlund T, Albrektsson B, Albrektsson T, Brånemark PI. Osseointegration of titanium implants. Acta Orthop Scand. 1986;57:285–9. - PubMed
    1. Levine BR, Hsu AR, Skipor AK, Hallab NJ, Paprosky WG, Galante JO, et al. Ten-year outcome of serum metal ion levels after primary total hip arthroplasty. J Bone Joint Surg Am. 2013;95:512–8. - PMC - PubMed
    1. Bianco PD, Ducheyne P, Cuckler JM. Titanium serum and urine levels in rabbits with a titanium implant in the absence of wear. Biomaterials. 1996;117:1937–42. - PubMed
    1. Misch CE. Contemporary Implant Dentistry. 3rd ed. St. Louis: Mosby; 2010. p. 40. 130-46, 245-50, 280.