Real-time breast sonography: application in 300 consecutive patients
- PMID: 3526839
- DOI: 10.2214/ajr.147.3.479
Real-time breast sonography: application in 300 consecutive patients
Abstract
Sonography, disappointing as a primary screening method, has emerged as the single most helpful adjunct to mammography in evaluation of the clinically and/or mammographically abnormal breast. Sonography can reliably diagnose simple cysts presenting as palpable masses or as indeterminate, nonpalpable lesions on mammography. However, differentiation of benign from malignant solid masses cannot be reliably accomplished by sonography. The expense of an automated breast sonographic scanner has deterred many radiologists from the purchase of such a unit. The authors have used both an automated breast scanner and a real-time 10-MHz hand-held unit. This paper describes their experience with the real-time unit, demonstrating both normal and pathologic anatomy. Special emphasis has been placed on the sonographic diagnosis of a simple cyst because this lesion was the cause of one-quarter of all palpable masses and nonpalpable, mammographically dominant masses. Cysts are sharply marginated and anechoic. Posterior enhancement visible in 78 of 80 cysts was not demonstrable on all images in 25% of cysts.
Similar articles
-
Automated and hand-held breast US: effect on patient management.Radiology. 1987 Oct;165(1):103-8. doi: 10.1148/radiology.165.1.3306779. Radiology. 1987. PMID: 3306779
-
Breast sonography.AJR Am J Roentgenol. 1991 Mar;156(3):449-55. doi: 10.2214/ajr.156.3.1899737. AJR Am J Roentgenol. 1991. PMID: 1899737 Review.
-
Combined mammographic-sonographic evaluation of breast masses.AJR Am J Roentgenol. 1977 Mar;128(3):409-17. doi: 10.2214/ajr.128.3.409. AJR Am J Roentgenol. 1977. PMID: 402833
-
[Real-time sonography in breast diagnosis. Indication and value].Wien Klin Wochenschr. 1984 Oct 26;96(20):772-8. Wien Klin Wochenschr. 1984. PMID: 6098081 German.
-
Sonography of malignant breast disease.Semin Ultrasound CT MR. 1989 Apr;10(2):119-31. Semin Ultrasound CT MR. 1989. PMID: 2697327 Review.
Cited by
-
Benign versus malignant breast masses: optical differentiation with US-guided optical imaging reconstruction.Radiology. 2005 Oct;237(1):57-66. doi: 10.1148/radiol.2371041236. Radiology. 2005. PMID: 16183924 Free PMC article.
-
Breast mass characterization using 3-dimensional automated ultrasound as an adjunct to digital breast tomosynthesis: a pilot study.J Ultrasound Med. 2013 Jan;32(1):93-104. doi: 10.7863/jum.2013.32.1.93. J Ultrasound Med. 2013. PMID: 23269714 Free PMC article.
-
Combination of digital mammography with semi-automated 3D breast ultrasound.Technol Cancer Res Treat. 2004 Aug;3(4):325-34. doi: 10.1177/153303460400300402. Technol Cancer Res Treat. 2004. PMID: 15270583 Free PMC article.
-
Ultrasound as the Primary Screening Test for Breast Cancer: Analysis From ACRIN 6666.J Natl Cancer Inst. 2015 Dec 28;108(4):djv367. doi: 10.1093/jnci/djv367. Print 2016 Apr. J Natl Cancer Inst. 2015. PMID: 26712110 Free PMC article. Clinical Trial.
-
Sonographic evaluation of breast nodules: comparison of conventional, real-time compound, and pulse-inversion harmonic images.Korean J Radiol. 2002 Jan-Mar;3(1):38-44. doi: 10.3348/kjr.2002.3.1.38. Korean J Radiol. 2002. PMID: 11919477 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical