Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2022 Mar;53(3):152-158.
doi: 10.3928/23258160-20220218-01. Epub 2022 Mar 1.

Pars Plana Vitrectomy Port Sizes: A Meta-Analysis of Randomized Controlled Trials

Meta-Analysis

Pars Plana Vitrectomy Port Sizes: A Meta-Analysis of Randomized Controlled Trials

Yuri V Chaban et al. Ophthalmic Surg Lasers Imaging Retina. 2022 Mar.

Abstract

Background and objective: The uptake of small-gauge (SG; ie, 23-gauge [23-G], 25-gauge [25-G], and 27-gauge [27-G]) pars plana vitrectomy (PPV) has grown. We aim to investigate the advantages and disadvantages of various PPV port sizes in a meta-analysis of randomized controlled trials (RCTs).

Materials and methods: A systematic literature search was performed for RCTs comparing PPV port sizes for any indication. Weighted mean differences (WMDs) and risk ratios (RRs) were calculated, and meta-analysis was performed with random-effects models.

Results: A total of 1,678 eyes from 22 RCTs were included. Risk-of-bias assessment found some concerns in 13 studies. Compared with 20-gauge PPV, there was no significant difference in the final or change in best-corrected visual acuity (BCVA; five studies analyzed each) relative to that of SG PPV. SG PPV was associated with a significantly greater incidence of hypotony (RR = 3.79; 95% confidence intervals [CI], 2.02 to 7.10; P < .0001; six studies) and choroidal detachment (RR = 5.65; 95% CI, 1.01 to 31.71; P = .05; three studies). Compared with 25-G PPV, there was no significant difference in BCVA at any time point with 23-G (two studies), and significantly more frequent port suturing was required with 23-G (RR = 0.46; 95% CI, 0.25 to 0.84; P = .01; two studies). Compared with 25-G PPV, 27-G was associated with a significantly better final BCVA (WMD = -0.06 logMAR; 95% CI, -0.11 to -0.01; P = .02; five studies) and a significantly lengthened surgery (WMD = 4.11 minutes; 95% CI, 0.18 to 8.05; P = .04; three studies).

Conclusions: There was no significant difference in visual or surgical outcomes following 20-gauge PPV relative to SG PPV (Grading of Recommendations, Assessment, Development, and Evaluation recommendation: low certainty), and there was an increased risk of postoperative complications with SG PPV (moderate certainty). Compared with 25-G PPV, 23-G required more frequent port suturing (moderate certainty), whereas 27-G may be associated with a better final BCVA but longer surgery (low and moderate certainty, respectively). [Ophthalmic Surg Lasers Imaging Retina. 2022;53:152-158.].

PubMed Disclaimer

Publication types

LinkOut - more resources