Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2022 Jun 1;28(3):340-347.
doi: 10.1097/MCC.0000000000000937. Epub 2022 Mar 11.

Cardiac output monitoring - invasive and noninvasive

Affiliations
Review

Cardiac output monitoring - invasive and noninvasive

Virendra K Arya et al. Curr Opin Crit Care. .

Abstract

Purpose of review: The purpose of this article is to review various contemporary cardiac output (CO) measurement technologies available and their utility in critically ill patients.

Recent findings: CO measurement devices can be invasive, minimally invasive, or noninvasive depending upon their method of CO measurement. All devices have pros and cons, with pulmonary artery catheter (PAC) being the gold standard. The invasive techniques are more accurate; however, their invasiveness can cause more complications. The noninvasive devices predict CO via mathematical modeling with several assumptions and are thus prone to errors in clinical situations. Recently, PAC has made a comeback into clinical practice especially in cardiac intensive care units (ICUs). Critical care echocardiography (CCE) is an upcoming tool that not only provides CO but also helps in differential diagnosis. Lack of proper training and nonavailability of equipment are the main hindrances to the wide adoption of CCE.

Summary: PAC thermodilution for CO measurement is still gold standard and most suitable in patients with cardiac pathology and with experienced user. CCE offers an alternative to thermodilution and is suitable for all ICUs; however, structural training is required.

PubMed Disclaimer

References

    1. Kobe J, Mishra N, Arya VK, et al. Cardiac output monitoring: technology and choice. Ann Card Anaesth 2019; 22:6–17.
    1. Thurman P. Mixed shock states: a case for the pulmonary artery catheter. AACN Adv Crit Care 2020; 31:67–74.
    1. Chatterjee K. The Swan-Ganz catheters: past, present, and future. A viewpoint. Circulation 2009; 119:147–152.
    1. Buhre W, Rossaint R. Perioperative management and monitoring in anesthesia. Lancet 2003; 362:1839–1846.
    1. Ahmed H, Kaufman D, Zenilman ME. A knot in the heart. Am Surg 2008; 74:235–236.