A novel antisymmetric 16-element transceiver dipole antenna array for parallel transmit cardiac MRI in pigs at 7 T
- PMID: 35277907
- DOI: 10.1002/nbm.4726
A novel antisymmetric 16-element transceiver dipole antenna array for parallel transmit cardiac MRI in pigs at 7 T
Abstract
To improve parallel transmit (pTx) and receive performance for cardiac MRI (cMRI) in pigs at 7 T, a dedicated transmit/receive (Tx/Rx), 16-element antisymmetric dipole antenna array, which combines L-shaped and straight dipoles, was designed, implemented, and evaluated in both cadavers and animals in vivo. Electromagnetic-field simulations were performed with the new 16-element dipole antenna array loaded with a pig thorax-shaped phantom and compared with an eight-element array of straight dipoles. The new dipole array was interfaced to a 7 T scanner in pTx mode (8Tx/16Rx). Imaging performance of the novel array was validated through MRI measurements in a pig phantom, an 85 kg pig cadaver, and two pigs in vivo (74 and 81 kg). Due to the improved decoupling between interleaved L-shaped and straight dipole elements, the 16-element dipole array fits within the same outer dimensions as an eight-element array of straight dipoles. This provides improvement of both transmit and receive characteristics and additional degrees of freedom for shimming. The antisymmetric dipole array demonstrated efficient suppression of destructive interferences in the field, with up to 25% improvement in the homogeneity achieved using static pTx-RFPA shimming in comparison with the hardware-adjusted state, which was optimized for single transmit. High-resolution (0.5 × 0.5 × 4 mm3 ) anatomical images of the heart after cardiac arrest proved good transmit and receive characteristics of the novel array design. Parallel imaging with an acceleration factor up to R = 6 was possible while maintaining a mean g factor of 1.55 within the pig heart. CINE images acquired in vivo in two pigs demonstrated SNR and parallel imaging capabilities similar to those of a reference 8Tx/16Rx dedicated loop array for cMRI in pigs.
Keywords: shimming; L-shaped dipole antenna; UHF; antisymmetric array; cardiac MRI; large animals; parallel transmission (pTx); pigs.
© 2022 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.
Similar articles
-
High-resolution imaging of the excised porcine heart at a whole-body 7 T MRI system using an 8Tx/16Rx pTx coil.MAGMA. 2023 Apr;36(2):279-293. doi: 10.1007/s10334-023-01077-z. Epub 2023 Apr 7. MAGMA. 2023. PMID: 37027119 Free PMC article.
-
A Novel Mono-surface Antisymmetric 8Tx/16Rx Coil Array for Parallel Transmit Cardiac MRI in Pigs at 7T.Sci Rep. 2020 Feb 20;10(1):3117. doi: 10.1038/s41598-020-59949-6. Sci Rep. 2020. PMID: 32080274 Free PMC article.
-
Design of a novel antisymmetric coil array for parallel transmit cardiac MRI in pigs at 7 T.J Magn Reson. 2019 Aug;305:195-208. doi: 10.1016/j.jmr.2019.07.004. Epub 2019 Jul 5. J Magn Reson. 2019. PMID: 31306985
-
Double-row 16-element folded-end dipole transceiver array for 3D RF shimming of the whole human brain at 9.4 T.NMR Biomed. 2023 Oct;36(10):e4981. doi: 10.1002/nbm.4981. Epub 2023 Jun 10. NMR Biomed. 2023. PMID: 37173759
-
A Review of Parallel Transmit Arrays for Ultra-High Field MR Imaging.IEEE Rev Biomed Eng. 2024;17:351-368. doi: 10.1109/RBME.2023.3244132. Epub 2024 Jan 12. IEEE Rev Biomed Eng. 2024. PMID: 37022919
Cited by
-
High-resolution imaging of the excised porcine heart at a whole-body 7 T MRI system using an 8Tx/16Rx pTx coil.MAGMA. 2023 Apr;36(2):279-293. doi: 10.1007/s10334-023-01077-z. Epub 2023 Apr 7. MAGMA. 2023. PMID: 37027119 Free PMC article.
-
Ultra-high field cardiac MRI in large animals and humans for translational cardiovascular research.Front Cardiovasc Med. 2023 May 15;10:1068390. doi: 10.3389/fcvm.2023.1068390. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37255709 Free PMC article.
References
REFERENCES
-
- Van de Moortele PF, Akgun C, Adriany G, et al. B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil. Magn Reson Med. 2005;54(6):1503-1518. doi:10.1002/mrm.20708
-
- Ibrahim TS, Lee R, Abduljalil AM, Baertlein BA, Robitaille PM. Dielectric resonances and B1 field inhomogeneity in UHFMRI: computational analysis and experimental findings. Magn Reson Imaging. 2001;19(2):219-226. doi:10.1016/S0730-725X(01)00300-9
-
- Xin SX, Huang QH, Gao Y, Li BG, Xu YK, Chen WF. Fetus MRI at 7 T: B1 shimming strategy and SAR safety implications. IEEE Trans Microw Theory Tech. 2013;61(5):2146-2152. doi:10.1109/TMTT.2013.2247053
-
- Ibrahim TS. Ultrahigh-field MRI whole-slice and localized RF field excitations using the same RF transmit array. IEEE Trans Med Imaging. 2006;25(10):1341-1347. doi:10.1109/TMI.2006.880666
-
- Mao W, Smith MB, Collins CM. Exploring the limits of RF shimming for high-field MRI of the human head. Magn Reson Med. 2006;56(4):918-922. doi:10.1002/mrm.21013
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical