. 2022 Jun 1;68(6):826-836.
doi: 10.1093/clinchem/hvac024.

Optimized Sequencing Adaptors Enable Rapid and Real-Time Metagenomic Identification of Pathogens during Runtime of Sequencing

Affiliations

Optimized Sequencing Adaptors Enable Rapid and Real-Time Metagenomic Identification of Pathogens during Runtime of Sequencing

Dong Zhang et al. Clin Chem. .

Abstract

Background: Metagenomic next-generation sequencing (mNGS) offers the promise of unbiased detection of emerging pathogens. However, in indexed sequencing, the sequential paradigm of data acquisition, demultiplexing, and analysis restrain read assignment in advance and real-time analysis, resulting in lengthy turnaround time for clinical metagenomic detection.

Methods: We described the utility of internal-index adaptors with different lengths of barcode in multiplex sequencing. The base composition for each position within these adaptors was well-balanced to ensure nucleotide diversity and optimal sequencing performance and to achieve the early assignment of reads by first sequencing the barcodes. Combined with an automated library preparation device, we delivered a rapid and real-time bioinformatics pathogen identification solution for the Illumina NextSeq platform. The diagnostic performance was evaluated by testing 153 lower respiratory tract specimens using mNGS in comparison to culture, 16S/internal transcribed spacer amplicon sequencing, and additional PCR-based tests.

Results: By calculating the average F1 scores of all read lengths under different threshold values, we established the optimal threshold for pathogens identification, and found that 36 bp was the optimal shortest read length for rapid mNGS analysis. Rapid detection had a negative percentage agreement and positive percentage agreement of 100% and 85.1% for bacteria and 97.4% and 80.3% for fungi, when compared to a composite standard. The rapid mNGS solution enabled accurate pathogen identification in about 9.1 to 10.1 h sample-to-answer turnaround time.

Conclusions: Optimized internal index adaptors combined with a real-time analysis pipeline provide a potential tool for a first-line test in critically ill patients.

Keywords: infection; metagenomic next-generation sequencing; pathogen detection; real-time analysis; turnaround time.