Palliation Plus Ventricular Assist Device Insertion in 15 Neonates and Infants With Functionally Univentricular Circulation

Affiliations

Palliation Plus Ventricular Assist Device Insertion in 15 Neonates and Infants With Functionally Univentricular Circulation

Mark S Bleiweis et al. Ann Thorac Surg. 2022 Oct.

Abstract

Background: We report 15 high-risk neonates and infants with functionally univentricular circulation stabilized with initial surgical palliation plus ventricular assist device (VAD) insertion (PALLIATION+VAD) in preparation for transplantation.

Methods: Fifteen functionally univentricular patients with ductal-dependent systemic circulation (8 hypoplastic left heart syndrome, 1 hypoplastic left heart syndrome-related malformation: 7 neonates, 2 infants) or ductal-dependent pulmonary circulation (6 hypoplastic right heart syndrome: 5 neonates, 1 infant) presented with anatomical and/or physiological features associated with increased risk for conventional univentricular palliation (large coronary sinusoids with ventricular-dependent coronary circulation, severe systemic atrioventricular valvar regurgitation, cardiogenic shock, or restrictive atrial septum). PALLIATION+VAD for patients with ductal-dependent systemic circulation was: VAD insertion plus application of bilateral pulmonary bands, stent placement in the arterial duct, and atrial septectomy, if needed. PALLIATION+VAD for patients with ductal-dependent pulmonary circulation was: VAD insertion plus stent placement in the arterial duct or systemic-to-pulmonary artery shunt with pulmonary arterioplasty, if needed.

Results: At PALLIATION+VAD, median age was 20 days (range, 4-143 days) and median weight was 3.47 kg (range, 2.43-4.86 kg). Ten patients (67%) survived and 5 patients (33%) died. All ten survivors are at home doing well after successful transplantation. Only 2 of 10 survivors (20%) required intubation >10 days after PALLIATION+VAD. Median length of VAD support for all 15 patients was 138 days (range, 56-226 days).

Conclusions: High-risk neonates with functionally univentricular hearts who are suboptimal candidates for conventional palliation can be successfully stabilized with pulsatile VAD insertion along with initial palliation while awaiting cardiac transplantation; these patients may be extubated, enterally nourished, and optimized for transplantation while on VAD.