Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jun 1;90(6):700-707.
doi: 10.1227/neu.0000000000001891. Epub 2022 Mar 25.

Safety and Efficacy of the Off-Label Use of Pipeline Embolization Device Based on the 2018 Food and Drug Administration-Approved Indications for Intracranial Aneurysms: A Single-Center Retrospective Cohort Study

Affiliations

Safety and Efficacy of the Off-Label Use of Pipeline Embolization Device Based on the 2018 Food and Drug Administration-Approved Indications for Intracranial Aneurysms: A Single-Center Retrospective Cohort Study

Alejandro Enriquez-Marulanda et al. Neurosurgery. .

Abstract

Background: The pipeline embolization device (PED; ev3/Covidien) has proven safe and effective for treating selected intracranial aneurysms. This device's versatility and popularity have driven increased interest in expanding the latest 2018 Food and Drug Administration-approved indications.

Objective: To compare "off-label" and "on-label" PED treatment.

Methods: Retrospective analysis of aneurysms treated with PED at a single center from 2013 to 2019. Comparisons were made based on the 2018 Food and Drug Administration-approved indications.

Results: A total of 492 treated aneurysms were included (65.2% on-label and 34.8% off-label). Aneurysm complete and near-complete occlusion rate was nonsignificantly lower in the off-label group (80.9% vs 85.7%; P = .19). Off-label treatment had higher rate of poor functional outcomes (modified Rankin Scale [mRS] >2: 10.3% vs 3.5%; P = .002). Although pretreatment mRS was already higher in the off-label group (5.3% vs 0.3%; P < .001) and there were no differences in mRS worsening during follow-up (5.5% vs 2.9%; P = .15). We also found a trend to a higher rate of intracranial hemorrhagic complications in the off-label group (4.7% vs 1.6%; P = .05), but there were no differences in hemorrhages requiring surgical intervention (1.8% vs 1.3%; P = .65). There were no differences in retreatment, thromboembolic complications, and mortality rates.

Conclusion: Off-label PED treatment may be considered for select aneurysms, which are challenging to treat with other techniques. These cases have similar complete and near-complete occlusion rates compared with on-label cases. There are, however, higher risks of poor functional outcomes despite similar rates of thromboembolic and hemorrhagic complications. This is partly explained by the significantly higher pretreatment mRS score in the off-label group.

PubMed Disclaimer

Comment in

References

    1. Kühn AL, Gounis MJ, Puri AS. Introduction: history and development of flow diverter technology and evolution. Neurosurgery. 2020;86(suppl 1):S3-S10.
    1. Nelson PK, Lylyk P, Szikora I, Wetzel SG, Wanke I, Fiorella D. The pipeline embolization device for the intracranial treatment of aneurysms trial. AJNR Am J Neuroradiol. 2011;32(1):34-40.
    1. Becske T, Kallmes DF, Saatci I, et al. Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology. 2013;267(3):858-868.
    1. Becske T, Brinjikji W, Potts MB, et al. Long-term clinical and angiographic outcomes following pipeline embolization device treatment of complex internal carotid artery aneurysms: five-year results of the pipeline for uncoilable or failed aneurysms trial. Neurosurgery. 2017;80(1):40-48.
    1. Patel PD, Chalouhi N, Atallah E, et al. Off-label uses of the pipeline embolization device: a review of the literature. Neurosurg Focus. 2017;42(6):E4.