. 1986 Nov;14(11):977-80.
doi: 10.1097/00003246-198611000-00014.

Effects of intermittent positive-pressure ventilation on cardiac output measurements by thermodilution

Effects of intermittent positive-pressure ventilation on cardiac output measurements by thermodilution

K Okamoto et al. Crit Care Med. 1986 Nov.

Abstract

Sequential thermodilution measurements of cardiac output in mechanically ventilated patients undergoing cardiac surgery demonstrated a cyclic modulation which correlated with changes in airway pressure, and was not affected by opening the pericardium. There was no satisfactory point for single measurements, which suggests that random thermodilution measurements of cardiac output during intermittent positive-pressure ventilation should be avoided, even when triplicate measurements are performed. To estimate the mean cardiac output, at least two measurements should be made at predetermined points of the ventilatory cycle. We recommend paired measurements at midinspiration and end-expiration.