. 2022 May:94:153-159.
doi: 10.1016/j.gaitpost.2022.03.011. Epub 2022 Mar 21.

Comparison of Azure Kinect and optical retroreflective motion capture for kinematic and spatiotemporal evaluation of the sit-to-stand test

Affiliations

Comparison of Azure Kinect and optical retroreflective motion capture for kinematic and spatiotemporal evaluation of the sit-to-stand test

Jacob Thomas et al. Gait Posture. 2022 May.

Abstract

Background: The sit-to-stand test (STS) is commonly used to evaluate functional capabilities within a variety of clinical populations. Traditionally STS is a timed test, limiting the depth of information which can be gained from its evaluation. The Azure Kinect has the potential to add in-depth analysis to STS. Despite these potential benefits, the recently released (2019) Azure Kinect has yet to be evaluated for its ability to accurately assess STS.

Research questions: Purposes of this work were to compare data captured during STS using both a 12 camera Vicon motion capture system and the Azure Kinect; and to calculate kinematic and spatiotemporal variables related to the four phases of the STS cycle.

Methods: Spatiotemporal and kinematic measures for STS were simultaneously collected by both devices for 15 participants. Cycle waveforms were compared for right and left hip and knee flexion/extension angular displacement, right and left hip and knee flexion/extension angular velocity, and knee-to-ankle separation ratio. Evaluated discrete outcome variables included: phase time points, maximum knee extension velocity from phases 3 to 4, medial-lateral pelvic sway range, and total time to completion. Waveform summary data were compared using R, R2, and RMSE. Discrete variables were analyzed using Spearman's Rank correlation coefficient.

Results: R and R2 values between the two systems indicated high levels of correlation (all R values > 0.711, all R2 values > 0.660). Although there was an overall high level of agreement between waveform shapes, high RMSE values indicated some minor tracking errors for Kinect within the STS cycle. Spearman's Rank correlation coefficient indicated high levels of correlation between the systems for discrete variables (all R values > 0.89), with the exception of medial-lateral pelvic sway range.

Significance: The Azure Kinect provides valuable insight into STS movement strategies allowing for improved precision in clinical decision making across multiple clinical populations.

Keywords: Azure Kinect; Motion capture; Sit-to-stand; Vicon.