Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jan;103(1):39-53.
doi: 10.1002/cyto.a.24554. Epub 2022 Apr 8.

Erythrocyte lysis and angle-resolved light scattering measured by scanning flow cytometry result to 48 indices quantifying a gas exchange function of the human organism

Affiliations
Free article

Erythrocyte lysis and angle-resolved light scattering measured by scanning flow cytometry result to 48 indices quantifying a gas exchange function of the human organism

Ekaterina S Yastrebova et al. Cytometry A. 2023 Jan.
Free article

Abstract

Molecular/cell level of gas exchange function assumes the accurate measurement of erythrocyte characteristics and rate constants concerning to molecules involved into the CO2 /O2 transport. Unfortunately, common hematology analyzers provide the measurement of eight indices of erythrocytes only and say little about erythrocyte morphology and nothing about rate constants of cellular function. The aim of this study is to demonstrate the ability of the Scanning Flow Cytometer (SFC) in the complete morphological analysis of mature erythrocytes and characterization of erythrocyte function via measurement of lysing kinetics. With this study we are introducing 48 erythrocyte indices. To provide the usability of application of the SFC in clinical diagnosis, we formed four categories of indices which are as follows: content/concentration (9 indices), morphology (26 indices), age (5 indices), and function (8 indices). The erythrocytes of 39 healthy volunteers were analyzed with the SFC to fix the first-ever reference intervals for the new indices introduced. The essential measurable reliability of the presented method is expressed in terms of errors of characteristics of single erythrocytes retrieved from the solution of the inverse light-scattering problem and errors of parameters retrieved from the fitting of the experimental kinetics by molecular-kinetics model of erythrocyte lysis.

Keywords: erythrocyte indices; gas exchange; inverse problem; light scattering; scanning flow cytometry.

PubMed Disclaimer

References

REFERENCES

    1. Chow EI. Kinetics of bicarbonate-chloride exchange across the human red blood cell membrane. J Gen Physiol. 1976;68:633-52.
    1. Wieth JO, Andersen OS, Brahm J, Bjerrum PJ, Borders CL. Chloride-bicarbonate exchange in red blood cells: physiology of transport and chemical modification of binding sites. Philos Trans R Soc B Biol Sci. 1982;299:383-99.
    1. Chernyshev AV, Tarasov PA, Semianov KA, Nekrasov VM, Hoekstra AG, Maltsev VP. Erythrocyte lysis in isotonic solution of ammonium chloride: theoretical modeling and experimental verification. J Theor Biol. 2008;251:93-107.
    1. Wang C-H, Popel AS. Effect of red blood cell shape on oxygen transport in capillaries. Math Biosci. 1993;116:89-110.
    1. Nabors LK, Baumgartner WA, Janke SJ, Rose JR, Wagner WW, Capen RL. Red blood cell orientation in pulmonary capillaries and its effect on gas diffusion. J Appl Physiol. 2003;94:1634-40.

Publication types

LinkOut - more resources