Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Nov;65(2):391-399.
doi: 10.1007/s10840-022-01190-4. Epub 2022 Apr 3.

Outcomes of a comprehensive strategy during repeat atrial fibrillation ablation

Affiliations

Outcomes of a comprehensive strategy during repeat atrial fibrillation ablation

Willy Weng et al. J Interv Card Electrophysiol. 2022 Nov.

Erratum in

Abstract

Background/purpose: Atrial fibrillation (AF) recurs post-ablation in 30-40% of patients. The approach to a repeat ablation, beyond isolation of reconnected pulmonary veins (PVs), is not well established. We sought to prospectively assess outcomes and predictors of recurrence among consecutive patients who underwent repeat AF ablation with a standardized approach.

Methods: This was a single-center prospective study of consecutive patients who underwent repeat AF ablation. Our protocol consisted of six steps: PV re-isolation, ablation of left atrial low-voltage areas (LVAs), ablation of isoproterenol-induced non-PV triggers, electrophysiology study (EPS) and ablation of induced AVNRT/AVRT, ablation of induced clinical atrial flutters, and lastly empiric ablation as per operator discretion if no other ablation was performed.

Results: Among 725 AF ablations performed during the study period, 74 were repeat ablations. Of those undergoing repeat ablation, 53 (72%) had PV reconnection, 30 (41%) had LVAs, seven (10%) had non-PV triggers, five (7%) had AVNRT, and 15 (20%) had typical atrial flutter. Following repeat ablation, arrhythmia-free survival was 65% at 1 year. The absence of PV reconnection was the only factor independently associated with recurrence after repeat ablation (recurrence rate 71%, adjusted OR 7.91, 95% CI 2.31-27.16, p = 0.001).

Conclusions: A comprehensive approach to repeat AF ablation including PV re-isolation, LVA ablation, non-PV trigger ablation, EPS, and flutter ablation was associated with a 65% 1-year arrhythmia-free survival. The absence of PV reconnection was the only independent predictor of arrhythmia recurrence. Further research is needed to identify therapies beyond PV isolation for patients undergoing repeat ablation.

Keywords: Arrhythmia recurrence; Atrial fibrillation; Catheter ablation.

PubMed Disclaimer

References

    1. Wokhlu A, Monahan KH, Hodge DO, Asirvatham SJ, Friedman PA, Munger TM, … Packer DL. Long-term quality of life after ablation of atrial fibrillation the impact of recurrence, symptom relief, and placebo effect. J Am Coll Cardiol. 2010;55(21):2308–2316. https://doi.org/10.1016/j.jacc.2010.01.040
    1. Wokhlu A, Hodge DO, Monahan KH, Asirvatham SJ, Friedman PA, Munger TM, … Packer DL. Long-term outcome of atrial fibrillation ablation: impact and predictors of very late recurrence. J Cardiovasc Electrophysiol. 2010;21(10):1071–1078. https://doi.org/10.1111/j.1540-8167.2010.01786.x
    1. Hussein AA, Saliba WI, Martin DO, Bhargava M, Sherman M, Magnelli-Reyes C, … Wazni O. Natural history and long-term outcomes of ablated atrial fibrillation. Circ Arrhythm Electrophysiol. 2011;4(3):271–278. https://doi.org/10.1161/CIRCEP.111.962100
    1. Bhargava M, Di Biase L, Mohanty P, Prasad S, Martin DO, Williams-Andrews M, … Natale A. Impact of type of atrial fibrillation and repeat catheter ablation on long-term freedom from atrial fibrillation: results from a multicenter study. Heart Rhythm. 2009;6(10):1403–1412. https://doi.org/10.1016/j.hrthm.2009.06.014
    1. Cappato R, Calkins H, Chen S-A, Davies W, Iesaka Y, Kalman J, … Biganzoli E. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol. 2010;3(1):32–38. https://doi.org/10.1161/CIRCEP.109.859116

LinkOut - more resources