A digital audit of emergency upper gastrointestinal fluoroscopy workflow in children with bilious vomiting
- PMID: 35402008
- PMCID: PMC8991196
- DOI: 10.4102/sajr.v26i1.2300
A digital audit of emergency upper gastrointestinal fluoroscopy workflow in children with bilious vomiting
Abstract
Background: Bilious vomiting in children requires an urgent evaluation with upper gastrointestinal (UGI) fluoroscopy as it may herald life-threatening midgut malrotation with volvulus (MMWV). There are no published data available on the duration of time-critical UGI workflow steps.
Objectives: A digital audit of workflow in emergency UGI contrast studies performed on children with bile-stained vomiting at a large South African teaching hospital.
Method: A retrospective study was conducted from 01 May 2012 - 31 May 2019. A customised search of the institutional radiology information system (RIS) defined all children with bilious vomiting who underwent emergency UGI fluoroscopy. Extracted RIS timestamps were used to calculate the median duration of the 'approval', 'waiting', 'study' and 'reporting' times. One-way analysis of variance and Chi-squared tests assessed the association between key parameters and the duration of workflow steps, with 5% significance (p < 0.05).
Results: Thirty-seven patients (n = 37) with median age 0.8 months were included, of whom 20 (54%) had an abnormal C-loop. The median 'total time' from physician request to report distribution was 107 min (interquartile range [IQR]: 67-173). The median 'approval' (6 min; IQR: 1-15) and 'reporting' (38 min; IQR: 17-91) times were the shortest and longest workflow steps, respectively. Abnormal C-loops (p = 0.04) and consultant referrals (p = 0.03) were associated with shorter 'approval' times. The neonatal 'waiting' time was significantly longer than that for older patients (p = 0.02).
Conclusion: The modern RIS is an excellent tool for time-critical workflow analyses, which can inform interventions for improved service delivery.
Keywords: bilious; malrotation; midgut volvulus; paediatric; upper gastrointestinal series; vomiting.
© 2022. The Authors.
Conflict of interest statement
The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.
Figures
Similar articles
-
Upper gastrointestinal series in healthy neonates with bilious vomiting-is it still obvious? A retrospective observational study.Acta Paediatr. 2023 Sep;112(9):1870-1876. doi: 10.1111/apa.16861. Epub 2023 Jun 10. Acta Paediatr. 2023. PMID: 37266967
-
Navigating Inconclusive Upper-Gastrointestinal Series in Infantile Bilious Vomiting: A Case Series on Intestinal Malrotation.Am J Case Rep. 2024 Mar 14;25:e943056. doi: 10.12659/AJCR.943056. Am J Case Rep. 2024. PMID: 38483097 Free PMC article.
-
Upper gastrointestinal fluoroscopic simulator for neonates with bilious emesis.Pediatr Radiol. 2015 Aug;45(9):1413-6. doi: 10.1007/s00247-015-3330-z. Epub 2015 Mar 22. Pediatr Radiol. 2015. PMID: 25796384
-
A Multi-institutional Case Series With Review of Point-of-Care Ultrasound to Diagnose Malrotation and Midgut Volvulus in the Pediatric Emergency Department.Pediatr Emerg Care. 2019 Jun;35(6):443-447. doi: 10.1097/PEC.0000000000001737. Pediatr Emerg Care. 2019. PMID: 30702647 Review.
-
[Volvulus and intestinal malrotation in the newborn].Pediatr Med Chir. 2005 Jan-Apr;27(1-2):62-6. Pediatr Med Chir. 2005. PMID: 16922046 Review. Italian.
Cited by
-
Malrotation with mid-gut volvulus and partial small bowel peritoneal membrane encapsulation.SA J Radiol. 2024 Aug 28;28(1):2936. doi: 10.4102/sajr.v28i1.2936. eCollection 2024. SA J Radiol. 2024. PMID: 39229460 Free PMC article.
References
-
- Intestinal malrotation and volvulus [homepage on the Internet]. c2019 [updated 2019 July; cited 2021 Sep 5]. Available from: https://www.cincinnatichildrens.org/health/i/intestinal-malrotation
LinkOut - more resources
Full Text Sources