Differences between Systems Using Optical and Capacitive Sensors in Treadmill-Based Spatiotemporal Analysis of Level and Sloping Gait
- PMID: 35408404
- PMCID: PMC9003327
- DOI: 10.3390/s22072790
Differences between Systems Using Optical and Capacitive Sensors in Treadmill-Based Spatiotemporal Analysis of Level and Sloping Gait
Abstract
Modern technology has enabled researchers to analyze gait with great accuracy and in various conditions based on the needs of the trainees. The purpose of the study was to investigate the agreement between systems equipped with optical and capacitive sensors in the analysis of treadmill-based level and sloping gait. The spatiotemporal parameters of gait were measured in 30 healthy college-level students during barefoot walking on 0% (level), -10% and -20% (downhill) and +10% and +20% (uphill) slopes at hiking-related speeds using an optoelectric cell system and an instrumented treadmill. Inter-system agreement was assessed using the Intraclass Correlation Coefficients (ICCs) and the 95% limits of agreement. Our findings revealed excellent ICCs for the temporal and between moderate to excellent ICCs for the spatial parameters of gait. Walking downhill and on a 10% slope demonstrated better inter-system agreement compared to walking uphill and on a 20% slope. Inter-system agreement regarding the duration of gait phases was increased by increasing the number of LEDs used by the optoelectric cell system to detect the contact event. The present study suggests that systems equipped with optical and capacitive sensors can be used interchangeably in the treadmill-based spatiotemporal analysis of level and sloping gait.
Keywords: gait analysis; inclined surfaces; inter-system agreement; treadmill walking.
Conflict of interest statement
The authors declare no conflict of interest.
Figures







Similar articles
-
Validity and reliability of a portable gait analysis system for measuring spatiotemporal gait characteristics: comparison to an instrumented treadmill.J Neuroeng Rehabil. 2016 Jan 20;13:6. doi: 10.1186/s12984-016-0115-z. J Neuroeng Rehabil. 2016. PMID: 26790409 Free PMC article.
-
Reproducibility of gait parameters at different surface inclinations and speeds using an instrumented treadmill system.Gait Posture. 2016 Feb;44:259-64. doi: 10.1016/j.gaitpost.2015.12.037. Epub 2015 Dec 29. Gait Posture. 2016. PMID: 27004668 Clinical Trial.
-
Validity Analysis of WalkerViewTM Instrumented Treadmill for Measuring Spatiotemporal and Kinematic Gait Parameters.Sensors (Basel). 2021 Jul 14;21(14):4795. doi: 10.3390/s21144795. Sensors (Basel). 2021. PMID: 34300534 Free PMC article.
-
Gait on slopes: Differences in temporo-spatial, kinematic and kinetic gait parameters between walking on a ramp and on a treadmill.Gait Posture. 2022 Jan;91:73-78. doi: 10.1016/j.gaitpost.2021.09.196. Epub 2021 Oct 6. Gait Posture. 2022. PMID: 34653877
-
Influence of body weight unloading on human gait characteristics: a systematic review.J Neuroeng Rehabil. 2018 Jun 20;15(1):53. doi: 10.1186/s12984-018-0380-0. J Neuroeng Rehabil. 2018. PMID: 29925400 Free PMC article.
Cited by
-
The effects of dynamic neuromuscular stabilization (DNS) approach on gait, lumbopelvic functional stability and abdominal core strength among adolescent idiopathic scoliosis (AIS): A randomized controlled trial study protocol.MethodsX. 2025 Jul 23;15:103529. doi: 10.1016/j.mex.2025.103529. eCollection 2025 Dec. MethodsX. 2025. PMID: 40761924 Free PMC article.
References
-
- Carbajales-Lopez J., Becerro-de-Bengoa-Vallejo R., Losa-Iglesias M.E., Casado-Hernández I., Benito-De Pedro M., Rodríguez-Sanz D., Calvo-Lobo C., Antolín M.S. The optogait motion analysis system for clinical assessment of 2D spatio-temporal gait parameters in young adults: A reliability and repeatability observational study. Appl. Sci. 2020;10:3726. doi: 10.3390/app10113726. - DOI
MeSH terms
LinkOut - more resources
Full Text Sources