Scoping review to evaluate existing measurement parameters and clinical outcomes of transtibial prosthetic alignment and socket fit
- PMID: 35412519
- DOI: 10.1097/PXR.0000000000000061
Scoping review to evaluate existing measurement parameters and clinical outcomes of transtibial prosthetic alignment and socket fit
Abstract
Introduction: Fit and alignment are observable objectives of the prosthesis rendering process for individuals with lower limb amputation. Nevertheless, there is a dearth of validated measures to directly assess the quality of this clinical procedure.
Objectives: The objectives of this scoping review are to evaluate existing measurement parameters and clinical outcomes used in investigations of transtibial socket fit or prosthetic alignment and to identify gaps in the literature regarding tools for evaluation of prosthetic fitting.
Study design: Scoping literature review.
Methods: A comprehensive search was conducted in the following databases: MEDLINE (through PubMed), Embase (through Elsevier), Scopus (through Elsevier), and Engineering Village (through Elsevier), resulting in 6107 studies to be screened.
Results: Sixty-three studies were included in the review. When measuring fit, studies most frequently reported on patient-reported comfort (n = 22) and socket size compared with the residual limb volume (n = 9). Alignment was most frequently measured by the prosthetists' judgment and/or use of an alignment jig (n = 34). The measurement parameters used to determine alignment or fit varied greatly among the included studies.
Conclusion: This review demonstrated that most measures of socket fit rely on a patient's self-report and may vary with biopsychosocial factors unrelated to the socket fitting process. Meanwhile, alignment is determined mostly by the prosthetist's judgment, paired with objective measurements, such as alignment jigs and gait analysis. Efforts to standardize and validate measures of these parameters of prosthetic fitting are vital to improving clinical practice and reporting outcomes.
Copyright © 2021 International Society for Prosthetics and Orthotics.
References
-
- Ziegler-Graham K, MacKenzie EJ, Ephraim PL, et al. Estimating the prevalence of limb loss in the United States: 2005 to 2050. Arch Phys Med Rehabil 2008; 89: 422–429.
-
- Pezzin LE, Dillingham TR, Mackenzie EJ, et al. Use and satisfaction with prosthetic limb devices and related services. Arch Phys Med Rehabil 2004; 85: 723–729.
-
- Turner S, McGregor AH. Perceived effect of socket fit on major lower limb prosthetic rehabilitation: a clinician and amputee perspective. Arch Rehabil Res Clin Transl 2020; 2: 100059.
-
- McLean JB, Larsen BG, Weathersby EJ, et al. Fluid volume management in prosthesis users: augmenting panel release with pin release. PM&R 2020; 12: 1236–1243.
-
- Sinha R, van den Heuvel WJ, Arokiasamy P. Factors affecting quality of life in lower limb amputees. Prosthet Orthot Int. 2011; 35: 90–96.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical