. 2022 Oct;48(5):4277-4282.
doi: 10.1007/s00068-022-01970-7. Epub 2022 Apr 16.

Agreement on fixation of pediatric supracondylar humerus fractures

Collaborators, Affiliations

Agreement on fixation of pediatric supracondylar humerus fractures

Willemijn Spierenburg et al. Eur J Trauma Emerg Surg. 2022 Oct.

Abstract

Background: Pediatric supracondylar humerus fractures (pSCHFs) may be challenging injuries to treat because of the potential residual deformity. There is debate regarding the technical aspects of adequate closed reduction and crossed Kirschner wire (K-wire) fixation.

Purpose: Do surgeons have an agreement on the aspects of the fixation of pSCHFs?

Methods: Radiographs of 20 patients from a cohort of 154 patients with pSCHFs treated with closed reduction and crossed K-wire fixation were selected. Forty-four surgeons viewed the postoperative radiographs and diagnosed the presence or absence of technical flaws and made a recommendation for or against reoperation. An expert panel of three orthopedic and trauma surgeons provided a reference standard for technical factors. Furthermore, final outcome 2 years after trauma was assessed.

Results: There was limited agreement on potential technical flaws (ICC 0.15-0.28), radiographic measures of alignment (ICC for anterior humeral line and Baumann angle of 0.37 and 0.23 respectively), the quality of postoperative reduction, position of the elbow in cast, and recommendation for repeat surgery (ICCs between 0.23 and 0.40). Sensitivity and specificity for these questions ranged from 0.59 to 0.90. There was no correlation between the voted quality of postoperative reduction and loss of reduction or final function.

Conclusions: Surgeons have limited agreement on the quality of postoperative results in pSCHFs and the indication for reoperation. Reviewing postoperative radiographs may present a good learning opportunity and could help improve skills, but it is not a validated method for quality control and has to be seen in light of clinical outcome.

Keywords: K-wire fixation; Pediatric; Science; Supracondylar humerus fractures.

PubMed Disclaimer

References

    1. Cheng JC, Ng BK, Ying SY, Lam PK. A 10-year study of the changes in the pattern and treatment of 6493 fractures. J Pediatr Orthop. 1999;19(3):344–50. - DOI
    1. Dimeglio A. Growth in pediatric orthopaedics. J Pediatr Orthop. 2001;21(4):549–55. - DOI
    1. Omid R, Choi PD, Skaggs DL. Supracondylar humeral fractures in children. J Bone Jt Surg Am. 2008;90(5):1121–32. https://doi.org/10.2106/JBJS.G.01354 . - DOI
    1. Gartland JJ. Management of supracondylar fractures of the humerus in children. Surg Gynecol Obstet. 1959;109(2):145–54. - PubMed
    1. Cuomo AV, Howard A, Hsueh S, Boutis K. Gartland type I supracondylar humerus fractures in children: is splint immobilization enough? Pediatr Emerg Care. 2012;28(11):1150–3. https://doi.org/10.1097/PEC.0b013e3182716fea . - DOI - PubMed