Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2022 Apr 19;145(16):1254-1284.
doi: 10.1161/CIRCULATIONAHA.121.058229. Epub 2022 Apr 18.

Percutaneous Transvalvular Microaxial Flow Pump Support in Cardiology

Affiliations
Review

Percutaneous Transvalvular Microaxial Flow Pump Support in Cardiology

Enzo Lüsebrink et al. Circulation. .

Abstract

The Impella device (Impella, Abiomed, Danvers, MA) is a percutaneous transvalvular microaxial flow pump that is currently used for (1) cardiogenic shock, (2) left ventricular unloading (combination of venoarterial extracorporeal membrane oxygenation and Impella concept), (3) high-risk percutaneous coronary interventions, (4) ablation of ventricular tachycardia, and (5) treatment of right ventricular failure. Impella-assisted forward blood flow increased mean arterial pressure and cardiac output, peripheral tissue perfusion, and coronary blood flow in observational studies and some randomized trials. However, because of the need for large-bore femoral access (14 F for the commonly used Impella CP device) and anticoagulation, the incidences of bleeding and ischemic complications are as much as 44% and 18%, respectively. Hemolysis is reported in as many as 32% of patients and stroke in as many as 13%. Despite the rapidly growing use of the Impella device, there are still insufficient data on its effect on outcome and complications on the basis of large, adequately powered randomized controlled trials. The only 2 small and also underpowered randomized controlled trials in cardiogenic shock comparing Impella versus intra-aortic balloon pump did not show improved mortality. Several larger randomized controlled trials are currently recruiting patients or are in preparation in cardiogenic shock (DanGer Shock [Danish-German Cardiogenic Shock Trial; NCT01633502]), left ventricular unloading (DTU-STEMI [Door-To-Unload in ST-Segment-Elevation Myocardial Infarction; NCT03947619], UNLOAD ECMO [Left Ventricular Unloading to Improve Outcome in Cardiogenic Shock Patients on VA-ECMO], and REVERSE [A Prospective Randomised Trial of Early LV Venting Using Impella CP for Recovery in Patients With Cardiogenic Shock Managed With VA ECMO; NCT03431467]) and high-risk percutaneous coronary intervention (PROTECT IV [Impella-Supported PCI in High-Risk Patients With Complex Coronary Artery Disease and Reduced Left Ventricular Function; NCT04763200]).

Keywords: cardiogenic shock; hemorrhage; myocardial infarction; ventricular tachycardia.

PubMed Disclaimer

MeSH terms

Associated data

LinkOut - more resources