Abstract
This article describes the numerical efforts made to investigate the influence of a left ventricular assist device (LVAD) on the patient-specific left heart's hemodynamics. Two different computational geometries with left heart have been simulated over the entire cardiac cycle (case 1: healthy heart without LVAD and case 2: diseased heart with LVAD). The blood flow was simulated by implementing Bird-Carreau non-Newtonian model. Simulation results show that implantation of LVAD pump imparts major influence on the hemodynamics of the heart; it also provides a cardiac output of 4.87 L/min even at the diastolic phase. Furthermore, post LVAD implantation, approximately eight times more wall shear stress, is noticed at the aorta during the ventricular systole. In particular, major changes in the fluidics are observed inside the aortic region. A possibility of flow stagnation is noticed near the aortic root during the diastolic phase due to the bisection of incoming bloodstreams from the outflow graft. The flow characteristics of the LVAD pump are also observed to be significantly different from the idealized simulations (idealized tubular inlet situation). The observation of this study can help in understanding post-implant critical hemodynamic issues due to pump performance and its subsequent impact on the heart. A simulation approach-based study has been performed to investigate the influence of LVAD on the hemodynamics of a heart. A 3D computational model of a patient-specific heart has been created from CT scan datasets for diastole and systole phases (a). An axial flow blood pump has been implanted computationally into the left heart (b). The implanted blood pump enhances the cardiac output and elevates shear generation (c) and (d).
Keywords: Blood pump; CFD; LVAD; Left heart; Ventricle.
© 2022. International Federation for Medical and Biological Engineering.
Similar articles
-
Left Ventricular Assist Device Flow Pattern Analysis Using a Novel Model Incorporating Left Ventricular Pulsatility.ASAIO J. 2021 Jul 1;67(7):724-732. doi: 10.1097/MAT.0000000000001341. ASAIO J. 2021. PMID: 33528162
-
Computational fluid dynamic study of hemodynamic effects on aortic root blood flow of systematically varied left ventricular assist device graft anastomosis design.J Thorac Cardiovasc Surg. 2015 Sep;150(3):696-704. doi: 10.1016/j.jtcvs.2015.05.034. Epub 2015 May 15. J Thorac Cardiovasc Surg. 2015. PMID: 26092505
-
A Computational Investigation of the Effects of Temporal Synchronization of Left Ventricular Assist Device Speed Modulation with the Cardiac Cycle on Intraventricular Hemodynamics.Ann Biomed Eng. 2024 Jun;52(6):1763-1778. doi: 10.1007/s10439-024-03489-x. Epub 2024 Mar 22. Ann Biomed Eng. 2024. PMID: 38517620
-
Blood damage in Left Ventricular Assist Devices: Pump thrombosis or system thrombosis?Int J Artif Organs. 2019 Mar;42(3):113-124. doi: 10.1177/0391398818806162. Epub 2018 Oct 24. Int J Artif Organs. 2019. PMID: 30354870 Review.
-
Device Management and Flow Optimization on Left Ventricular Assist Device Support.Crit Care Clin. 2018 Jul;34(3):453-463. doi: 10.1016/j.ccc.2018.03.002. Crit Care Clin. 2018. PMID: 29907276 Review.
Cited by
-
Optimization of photon counting CT for cardiac imaging in patients with left ventricular assist devices: An in-depth assessment of metal artifacts.J Appl Clin Med Phys. 2024 Jul;25(7):e14386. doi: 10.1002/acm2.14386. Epub 2024 May 13. J Appl Clin Med Phys. 2024. PMID: 38739330 Free PMC article.
References
-
- Ambrosy AP, Fonarow GC, Butler J et al (2014) The global health and economic burden of hospitalizations for heart failure: lessons learned from hospitalized heart failure registries. J Am Coll Cardiol 63(12):1123–1133 - DOI
-
- Trivedi JR, Cheng A, Singh R, Williams ML, Slaughter MS (2014) Survival on the heart transplant waiting list: impact of continuous flow left ventricular assist device as bridge to transplant. Ann Thorac Surg 98:830–834 - DOI
-
- InformedHealth.org [Internet]. Cologne, Germany: Institute for Quality and Efficiency in Health Care (IQWiG); 2006-. Types of heart failure. 2018 Jan 25. Available from: https://www.ncbi.nlm.nih.gov/books/NBK481485/
-
- Sen A, Larson JS, Kashani KB et al (2013) Mechanical circulatory assist devices: a primer for critical care and emergency physicians. Crit Care 20(1):153 - DOI
-
- Stöhr EJ, McDonnell BJ, Colombo PC, Willey JZ (2019) CrossTalk proposal: blood flow pulsatility in left ventricular assist device patients is essential to maintain normal brain physiology. J Physiol 597:353–356 - DOI
MeSH terms