Abstract
Purpose: To prevent hemorrhagic complications, hemostatic agents (HAs) have been widely used in recent years. The use of HAs can lead to false-positive results on postoperative imaging. There exists only 1 study in the literature evaluating these applications during surgical procedures. Therefore, we aimed to evaluate the postoperative imaging features of polysaccharide-based HAs in thoracic surgery patients who have had 18F-FDG PET/CT scans.
Patients and methods: Two hundred nine consecutive patients who underwent thoracic surgery were enrolled in this study. A topical polysaccharide-based HA was applied to the surgical bed for all of the patients. The patients diagnosed with cancer were followed up with subsequent thoracic CT scans, and 42 of these patients were also imaged with 18F-FDG PET/CT, which then comprised the main study group. Due to suspicion of metastasis, 19/42 patients were reoperated or rebiopsied. The latest histopathological findings were accepted as criterion standard, and previous FDG PET/CT images were retrospectively reevaluated.
Results: Polysaccharide-based HAs that appear as amorphous basophilic material were identified in histopathological samples of 11/19 patients. Lymphocytes, plasma cells, and histiocytes, which formed foreign body reaction and/or foreign body granuloma, indicating the presence of chronic inflammation, were seen in all of the samples. 18F-FDG PET/CT showed increased FDG uptake in all of these lesions.
Conclusions: Despite the inconsistency of the literature, polysaccharide-based HAs can be demonstrated in human surgical specimens as amorphous basophilic materials even after a long time from the initial surgical procedure. These agents almost always cause chronic inflammatory changes. In addition, these agents may mimic "false-positive" findings on postoperative FDG PET/CT scans.
Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.
Conflict of interest statement
Conflicts of interest and sources of funding: none declared.
References
-
- Antisdel JL, West-Denning JL, Sindwani R. Effect of microporous polysaccharide hemospheres (MPH) on bleeding after endoscopic sinus surgery: randomized controlled study. Otolaryngol Head Neck Surg . 2009;141:353–357.
-
- Benlier E, Top H, Aygit AC, et al. Microvascular anastomosis with minimal suture and arista: an experimental study. J Reconstr Microsurg . 2007;23:311–315.
-
- Emmez H, Tonge M, Tokgoz N, et al. Radiological and histopathological comparison of microporous polysaccharide hemospheres and oxidized regenerated cellulose in the rabbit brain: a study of efficacy and safety. Turk Neurosurg . 2010;20:485–491.
-
- Ereth MH, Schaff M, Ericson EF, et al. Comparative safety and efficacy of topical hemostatic agents in a rat neurosurgical model. Neurosurgery . 2008;63:369–372.
-
- Burghuber CK, Kandioler D, Strobl S, et al. Standardized intraoperative application of an absorbable polysaccharide hemostatic powder to reduce the incidence of lymphocele after kidney transplantation—a prospective trial. Transpl Int . 2019;32:59–65.
MeSH terms