[High-rank technology in the medicine - the impact of continuous glucose monitoring system alarm settings values on glycemic control in type 1 diabetes patients: a systematic review]
- PMID: 35459377
[High-rank technology in the medicine - the impact of continuous glucose monitoring system alarm settings values on glycemic control in type 1 diabetes patients: a systematic review]
Abstract
Alarms in continuous glucose monitoring systems (CGM) represent a very important feature enabling to patients with diabetes who use these systems to keep their blood glucose level in the target range and to avoid excursion to hypoglycemia or hyperglycemia. The possibility to warn the patient that the target range has been crossed means one of the main advantages of CGM over the selfmonitoring of blood glucose with personal glucometers, but also (so far) flash glucose monitoring systems. However, there is surprisingly few studies concerning specifically the relationship between the alarms settings and glucose control. Therefore, there are currently no recommendations nor guidelines for optimal settings of alarms in CGM. Limited number of studies suggest that the setting of the hypoglycemia alarm to a level higher than 4 mmol/L is associated with lower frequency and shorter duration of hypoglycemia, and may be temporarily increased to 6 mmol/L in patients with impaired hypoglycemia awareness.
Keywords: CGM; alarms; diabetes; hyperglycemia; hypoglycemia; type 2 diabetes.
Similar articles
-
Intermittent-scanned continuous glucose monitoring with low glucose alarms decreases hypoglycemia incidence in middle-aged adults with type 1 diabetes in real-life setting.J Diabetes Complications. 2023 Feb;37(2):108385. doi: 10.1016/j.jdiacomp.2022.108385. Epub 2022 Dec 26. J Diabetes Complications. 2023. PMID: 36603333
-
Continuous Glucose Monitoring Alarms in Adults with Type 1 Diabetes: User Characteristics and the Impact of Hypoglycemia and Hyperglycemia Alarm Thresholds on Glycemic Control.Diabetes Technol Ther. 2024 May;26(5):313-323. doi: 10.1089/dia.2023.0460. Epub 2024 Mar 8. Diabetes Technol Ther. 2024. PMID: 38156962
-
Switching from Flash Glucose Monitoring to Continuous Glucose Monitoring on Hypoglycemia in Adults with Type 1 Diabetes at High Hypoglycemia Risk: The Extension Phase of the I HART CGM Study.Diabetes Technol Ther. 2018 Nov;20(11):751-757. doi: 10.1089/dia.2018.0252. Epub 2018 Sep 28. Diabetes Technol Ther. 2018. PMID: 30265562 Free PMC article. Clinical Trial.
-
Can the Use of Continuous Glucose Monitoring Improve Glycemic Control in Patients with Type 1 and 2 Diabetes Receiving Dialysis?Nephron. 2023;147(2):91-96. doi: 10.1159/000525676. Epub 2022 Jul 13. Nephron. 2023. PMID: 35830847 Review.
-
Effectiveness of Continuous Glucose Monitoring on Metrics of Glycemic Control in Type 2 Diabetes Mellitus: A Systematic Review and Meta-analysis of Randomized Controlled Trials.J Clin Endocrinol Metab. 2024 Mar 15;109(4):1119-1131. doi: 10.1210/clinem/dgad652. J Clin Endocrinol Metab. 2024. PMID: 37987208
Cited by
-
Glucose alarms approach with flash glucose monitoring system: a narrative review of clinical benefits.Diabetol Metab Syndr. 2025 Jul 16;17(1):276. doi: 10.1186/s13098-025-01797-3. Diabetol Metab Syndr. 2025. PMID: 40671052 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical