Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Oct 3;39(10):2196-2207.
doi: 10.1080/09593985.2022.2072251. Epub 2022 May 3.

Subacromial space measured by ultrasound imaging in asymptomatic subjects and patients with subacromial shoulder pain: an inter-rater reliability study

Affiliations

Subacromial space measured by ultrasound imaging in asymptomatic subjects and patients with subacromial shoulder pain: an inter-rater reliability study

Claudia Cavaggion et al. Physiother Theory Pract. .

Abstract

Background: Acromiohumeral distance (AHD) and supraspinatus tendon thickness (STT) measured by ultrasound (US) can be combined in the occupation ratio (OR). Inter-rater reliability on these subacromial measures depends on the US experience of raters and on the subject status, differing between asymptomatic or patients with subacromial shoulder pain (SSP).

Objective: To evaluate inter-rater reliability between two raters with different US experience (experienced examiner and novice examiner).

Methods: In total, 20 asymptomatic subjects (controls) and 21 patients with SSP were examined on one shoulder. Inter-rater reliability was evaluated with intraclass correlation coefficient (ICC).

Results: ICC for controls was good for AHD at rest and at 60° (0.76-0.77), moderate for STT and AHD at 60° with weights (0.53-0.72), while OR was poorly reliable (below 0.44). ICC for SSP was moderate for AHD at rest and at 60°, STT, OR at rest and at 60° (0.52-0.74) and poor for AHD at 60° with weights and OR at 60° with weights (0.33-0.36). Bland-Altman plots showed systematic bias.

Conclusion: Inter-rater reliability varied largely from poor to good between two examiners with different US experience. Clinicians might use the US as additional tool for detecting the subacromial structures, but a structured training including also symptomatic subjects is suggested. Researchers may further investigate the OR in matched case-control studies, and an overall agreement phase is recommended before starting the inter-rater reliability phase.

Keywords: Acromiohumeral distance; reproducibility of results; shoulder pain; supraspinatus tendon; ultrasonography.

PubMed Disclaimer

LinkOut - more resources