Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2023 Feb;40(2):140-146.
doi: 10.1136/emermed-2021-212281. Epub 2022 May 6.

Diagnostic accuracy of point-of-care ultrasound for paediatric testicular torsion: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Diagnostic accuracy of point-of-care ultrasound for paediatric testicular torsion: a systematic review and meta-analysis

Takaaki Mori et al. Emerg Med J. 2023 Feb.

Abstract

Background: Previous studies have examined the utility of ultrasonography performed by radiologists for diagnosing paediatric testicular torsion. While point-of-care ultrasound (POCUS) is used in paediatric emergency medicine, its diagnostic accuracy is still unknown.

Objectives: The present systematic review and meta-analysis aimed to clarify the accuracy of POCUS in diagnosing testicular torsion in children.

Methods: Following the Preferred Reporting Items for Systematic Review and Meta-analysis of Diagnostic Test Accuracy guidelines, a systematic review was performed using the indices of MEDLINE, EMBASE plus EMBASE classics, PubMed and the Cochrane database from inception to November 2020. Any study investigating the diagnostic accuracy of POCUS for paediatric testicular torsion was extracted. The primary outcome was the assessment of the diagnostic accuracy of POCUS for paediatric testicular torsion. The pooled sensitivity and specificity were calculated. Quality analysis was conducted using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).

Results: Four studies enrolling 784 patients in total were included. The pooled sensitivity, specificity, and positive and negative likelihood ratios of POCUS were 98.4% (95% CI: 88.5% to 99.8%), 97.2% (95% CI: 87.2% to 99.4%), 34.7 (95% CI: 7.4 to 164.4) and 0.017 (95% CI: 0.002 to 0.12), respectively. Risk-of-bias assessment using QUADAS-2 revealed that two of the studies had a high risk of bias in patient selection.

Conclusion: The present systematic review and meta-analysis showed that POCUS had high sensitivity and specificity for identifying testicular torsion in paediatric patients although the risk of bias was high in the studies analysed.

Keywords: Ultrasonography; pediatric emergency medicine.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

Similar articles

Cited by

LinkOut - more resources