. 2022 Aug;29(8):2431-2438.
doi: 10.1111/ene.15387. Epub 2022 May 25.

Concordance of cerebrospinal fluid real-time quaking-induced conversion across the European Creutzfeldt-Jakob Disease Surveillance Network

Affiliations

Concordance of cerebrospinal fluid real-time quaking-induced conversion across the European Creutzfeldt-Jakob Disease Surveillance Network

Neil McKenzie et al. Eur J Neurol. 2022 Aug.

Abstract

Background and purpose: Cerebrospinal fluid (CSF) real-time quaking-induced conversion (RT-QuIC) has a high degree of sensitivity and specificity for the diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD) and this has led to its being included in revised European CJD Surveillance Network diagnostic criteria for sCJD. As CSF RT-QuIC becomes more widely established, it is crucial that the analytical performance of individual laboratories is consistent. The aim of this ring-trial was to ascertain the degree of concordance between European countries undertaking CSF RT-QuIC.

Methods: Ten identical CSF samples, seven from probable or neuropathologically confirmed sCJD and three from non-CJD cases, were sent to 13 laboratories from 11 countries for RT-QuIC analysis. A range of instrumentation and different recombinant prion protein substrates were used. Each laboratory analysed the CSF samples blinded to the diagnosis and reported the results as positive or negative.

Results: All 13 laboratories correctly identified five of the seven sCJD cases and the remaining two sCJD cases were identified by 92% of laboratories. Of the two sCJD cases that were not identified by all laboratories, one had a disease duration >26 months with a negative 14-3-3, whilst the remaining case had a 4-month disease duration and a positive 14-3-3. A single false positive CSF RT-QuIC result was observed in this study.

Conclusions: This study shows that CSF RT-QuIC demonstrates an excellent concordance between centres, even when using a variety of instrumentation, recombinant prion protein substrates and CSF volumes. The adoption of CSF RT-QuIC by all CJD surveillance centres is recommended.

Keywords: Creutzfeldt-Jakob disease; cerebrospinal fluid; prion; real-time quaking-induced conversion.

PubMed Disclaimer

Conflict of interest statement

None.

References

    1. Atarashi R, Satoh K, Sano K, et al. Ultrasensitive human prion detection in cerebrospinal fluid by real‐time quaking‐induced conversion. Nat Med. 2011;17:175‐178. doi:10.1038/nm.2294 - DOI - PubMed
    1. Hermann P, Appleby B, Brandel J‐P, et al. Sporadic Creutzfeldt–Jakob disease: advanced biomarkers and diagnostic guidelines. Lancet Neurol. 2021;20:235‐246. doi:10.1016/S1474-4422(20)30477-4 - DOI - PMC - PubMed
    1. Wilham JM, Orrú CD, Bessen RA, et al. Rapid end‐point quantitation of prion seeding activity with sensitivity comparable to bioassays. PLoS Pathog. 2010;6:e1001217. doi:10.1371/journal.ppat.1001217 - DOI - PMC - PubMed
    1. McGuire LI, Peden AH, Orrú CD, et al. RT‐QuIC analysis of cerebrospinal fluid in sporadic Creutzfeldt–Jakob disease. Ann Neurol. 2012;72:278‐285. doi:10.1002/ana.23589 - DOI - PMC - PubMed
    1. Orrú CD, Bongianni M, Tonoli G, et al. A test for Creutzfeldt–Jakob disease using nasal brushings. N Engl J Med. 2014;371:519‐529. doi:10.1056/NEJMoa1315200 - DOI - PMC - PubMed