Ventricular assist by cardiac cycle-specific increases in intrathoracic pressure
- PMID: 3552466
- DOI: 10.1378/chest.91.5.709
Ventricular assist by cardiac cycle-specific increases in intrathoracic pressure
Abstract
Changes in intrathoracic pressure can influence cardiac performance by altering ventricular loading conditions. Since ventricular loading, both from systemic venous return (preload) and from left ventricular wall stress (afterload), varies during the cardiac cycle, we reasoned that appropriately placed, phasic, cardiac cycle-specific (synchronous) increases in intrathoracic pressure might augment ventricular ejection in acute ventricular failure. Recent studies in animals suggest that synchronous increases in intrathoracic pressure during systole increase ejection. We compared the hemodynamic effect of synchronous increases in intrathoracic pressure with similar increases delivered at random in the cardiac cycle in patients with congestive cardiomyopathy (n = 9). Intrathoracic pressure was estimated by measuring esophageal pressure. High-frequency jet ventilation (HFJV) synchronized with the electrocardiogram (synchronous HFJV) was compared with HFJV at a fixed frequency within 15 percent of the heart rate (asynchronous HFJV) and with intermittent positive-pressure breathing (IPPB) (tidal volume = 10 ml/kg; f = 15). All forms of ventilation resulted in the same mean airway pressure and esophageal pressure. Mean pulmonary arterial occlusion pressure and arterial pressure were constant in all conditions. Cardiac output was greater with synchronous HFJV than with either IPPB or asynchronous HFJV (4.5 +/- 0.7 L/min compared with 3.5 +/- 0.7 and 3.4 +/- 0.6 L/min [mean +/- SE], respectively; p less than 0.05). Mixed venous oxygen saturation covaried with cardiac output (p less than 0.05), such that calculated oxygen consumption remained constant for all conditions. We conclude that synchronous HFJV augments cardiac output more efficiently than do similar increases in intrathoracic pressure delivered randomly in the cardiac cycle.
Similar articles
-
Hemodynamic effects of cardiac cycle-specific increases in intrathoracic pressure.J Appl Physiol (1985). 1986 Feb;60(2):604-12. doi: 10.1152/jappl.1986.60.2.604. J Appl Physiol (1985). 1986. PMID: 3512512
-
Hemodynamic effects of synchronized high-frequency jet ventilation compared with low-frequency intermittent positive-pressure ventilation after myocardial revascularization.Anesthesiology. 2000 Jan;92(1):24-30. doi: 10.1097/00000542-200001000-00010. Anesthesiology. 2000. PMID: 10638895
-
Hemodynamic effects of high-frequency jet ventilation.Anesth Analg. 1983 Mar;62(3):298-304. Anesth Analg. 1983. PMID: 6338759
-
The influence of high-frequency jet ventilation with varying cardiac-cycle specific synchronization on cardiac output in ARDS.Chest. 1997 Dec;112(6):1600-6. doi: 10.1378/chest.112.6.1600. Chest. 1997. PMID: 9404760 Review.
-
Cardiovascular issues in respiratory care.Chest. 2005 Nov;128(5 Suppl 2):592S-597S. doi: 10.1378/chest.128.5_suppl_2.592S. Chest. 2005. PMID: 16306058 Review.
Cited by
-
Cardiopulmonary Interactions in Children with Heart Failure.Curr Cardiol Rev. 2016;12(2):104-6. doi: 10.2174/1573403x12666151119164802. Curr Cardiol Rev. 2016. PMID: 26585038 Free PMC article. Review.
-
Synchronized diaphragmatic stimulation for heart failure using the VisONE system: a first-in-patient study.ESC Heart Fail. 2022 Aug;9(4):2207-2214. doi: 10.1002/ehf2.13984. Epub 2022 May 26. ESC Heart Fail. 2022. PMID: 35619238 Free PMC article.
-
Discovering the Clinical Relevance of Heart-Lung Interactions.Anesthesiology. 2024 Feb 1;140(2):284-290. doi: 10.1097/ALN.0000000000004789. Anesthesiology. 2024. PMID: 38193738 Free PMC article.
-
Consensus conference on mechanical ventilation--January 28-30, 1993 at Northbrook, Illinois, USA. Part 2.Intensive Care Med. 1994;20(2):150-62. doi: 10.1007/BF01707673. Intensive Care Med. 1994. PMID: 8201097 Review. No abstract available.
-
Synchronized Diaphragmatic Stimulation for Heart Failure With a Reduced Left Ventricular Ejection Fraction Using the VisONE System: A First-in-Patient Study With Extended Population.Struct Heart. 2022 Oct 31;6(6):100103. doi: 10.1016/j.shj.2022.100103. eCollection 2022 Nov. Struct Heart. 2022. PMID: 37288118 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources