Sensitivity and specificity of heat and moisture exchange filters sampling for SARS-CoV-2 detection in mechanically ventilated COVID-19 patients
- PMID: 35534384
- PMCID: PMC9008093
- DOI: 10.1016/j.jmii.2022.04.002
Sensitivity and specificity of heat and moisture exchange filters sampling for SARS-CoV-2 detection in mechanically ventilated COVID-19 patients
Abstract
We assessed the sensitivity and specificity of SARS-CoV-2 detection by polymerase chain reaction in heat and moisture exchange filters (HMEF) in mechanically ventilated COVID-19 patients. We showed that testing HMEF might obviate the need for a tracheal sample to affirm that a patient is not ready to end isolation.
Keywords: Heat and moisture exchange filters; Intensive care; Isolation; Mechanical ventilation; RT-PCR; SARS-CoV-2.
Copyright © 2022. Published by Elsevier B.V.
Conflict of interest statement
Declaration of competing interest All authors report no conflicts of interest relevant to this article.
Figures
References
-
- Morán I., Bellapart J., Vari A., Mancebo J. Heat and moisture exchangers and heated humidifiers in acute lung injury/acute respiratory distress syndrome patients. Effects on respiratory mechanics and gas exchange. Intensive Care Med. 2006;32:524–531. - PubMed
-
- Bastarache J.A., McNeil J.B., Plosa E.J., Sucre J.S., Kerchberger V.E., Habegger L.E., et al. Standardization of methods for sampling the distal airspace in mechanically ventilated patients using heat moisture exchange filter fluid. Am J Physiol Lung Cell Mol Physiol. 2021;320:L785–L790. - PMC - PubMed