Screening cornea donors for antibodies against human immunodeficiency virus. Efficacy of ELISA testing of cadaveric sera and aqueous humor
- PMID: 3554092
- DOI: 10.1016/s0161-6420(87)33489-x
Screening cornea donors for antibodies against human immunodeficiency virus. Efficacy of ELISA testing of cadaveric sera and aqueous humor
Abstract
Coded cadaveric sera from 35 patients with acquired immunodeficiency syndrome (AIDS), from 45 cadavers at high risk of human immunodeficiency virus (HIV) infection, and from 262 cadavers without known signs or risk of AIDS were assessed using three commercially available enzyme-linked immunosorbent assays (ELISA) kits and Western blot analysis. Greater than 94% sensitivity and 99% specificity was achieved with each of the ELISA test kits using cadaveric sera. The Western blot method gave 97.1% sensitivity compared with the autopsy-proven diagnosis of AIDS. Positive results were obtained on sera from AIDS cadavers even if the time of blood draw was delayed 35 hours from death and the time of sera preparation was delayed up to 176 days. False-negative or false-positive ELISA results did not appear to correlate with hemolysis or any parameter of sera preparation. In contrast to the high sensitivity in testing sera, only 16 to 26% of aqueous humor samples from AIDS cadavers were ELISA-positive and 79% were positive by Western blot. These results indicate that three commercially available ELISA test kits are an effective means of screening cadaveric sera for antibodies to HIV, but that aqueous humor cannot be reliably substituted for cadaveric sera to screen potential cornea donors by an ELISA assay.
Similar articles
-
New developments in serologic screening of corneal donors for HIV-1 and hepatitis B virus infections.Ophthalmology. 1992 Jun;99(6):879-88. doi: 10.1016/s0161-6420(92)31878-0. Ophthalmology. 1992. PMID: 1630777
-
Evaluation of serological screening of cadaveric sera for donor selection for cornea transplantation.J Med Virol. 1999 Jul;58(3):291-5. doi: 10.1002/(sici)1096-9071(199907)58:3<291::aid-jmv16>3.0.co;2-d. J Med Virol. 1999. PMID: 10447426
-
[Comparison of two ELISA kits for the demonstration of antibodies against LAV/HTLV-III].Zentralbl Bakteriol Mikrobiol Hyg A. 1987 Apr;264(1-2):196-200. Zentralbl Bakteriol Mikrobiol Hyg A. 1987. PMID: 3307232 German.
-
[HIV (HTLV III/LAV) serology: experiences based on more than 42,000 tests].Wien Klin Wochenschr. 1987 Aug 7;99(15):536-9. Wien Klin Wochenschr. 1987. PMID: 3310415 Review. German.
-
Status of current clinical tests for human immunodeficiency virus (HIV): applications and limitations.Ann Clin Lab Sci. 1987 Sep-Oct;17(5):279-85. Ann Clin Lab Sci. 1987. PMID: 3314657 Review.
Cited by
-
Human immunodeficiency virus and its effects on the visual system.Infect Dis Rep. 2012 Mar 8;4(1):e25. doi: 10.4081/idr.2012.e25. eCollection 2012 Jan 2. Infect Dis Rep. 2012. PMID: 24470932 Free PMC article. Review.
-
Detection of HIV in human vitreous.Int Ophthalmol. 1993 Apr;17(2):101-4. doi: 10.1007/BF00942783. Int Ophthalmol. 1993. PMID: 8407115
-
Surveillance of HIV and viral hepatitis by analysis of samples from drug related deaths.Eur J Epidemiol. 2006;21(5):383-7. doi: 10.1007/s10654-006-9009-x. Epub 2006 Jun 9. Eur J Epidemiol. 2006. PMID: 16763882
Publication types
MeSH terms
Substances
LinkOut - more resources