Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2022 Sep;19(9):1484-1490.
doi: 10.1016/j.hrthm.2022.04.033. Epub 2022 May 10.

Left bundle branch area pacing in patients with atrioventricular conduction disease: A prospective multicenter study

Affiliations
Multicenter Study

Left bundle branch area pacing in patients with atrioventricular conduction disease: A prospective multicenter study

Alexandre Raymond-Paquin et al. Heart Rhythm. 2022 Sep.

Abstract

Background: The reported success rate of His-bundle pacing (HBP) in patients with infranodal atrioventricular (AV) conduction disease is only 52%-76%. The success rate of left bundle branch area pacing (LBBAP) in this cohort is not well studied.

Objective: The purpose of this study was to evaluate the feasibility, safety, and electrophysiological characteristics of LBBAP in patients with AV conduction disease.

Methods: Patients with AV conduction disease referred for pacemaker implantation at 2 centers between February 2019 and June 2021 were considered for LBBAP. Baseline demographic characteristics, procedural success rates, electrophysiological parameters, and complications were assessed.

Results: LBBAP was successful in 340 of 364 patients (93%). Mean age was 72 ± 13 years, and mean follow-up was 331 ± 244 days. Pacing indications were Mobitz I in 27 patients (7%), Mobitz II or 2:1 AV block or high-grade AV block in 94 patients (26%), complete heart block in 199 patients (55%), and sick sinus syndrome with isolated bundle branch block in 44 patients (12%). Left bundle branch block and right bundle branch block were present in 57 patients (16%) and 140 patients (38%), respectively. Procedural success rates did not differ between indications (92.6%, 93.6%, 92.9%, and 95%, respectively) or between patients with narrow (<120 ms) vs wide QRS (≥120 ms). Mean LBBAP threshold was 0.77 ± 0.34 V at 0.4 ms at implant and remained stable during follow-up. There were 4 (1.2%) acute LBBAP lead dislodgments.

Conclusion: LBBAP is safe and feasible with high success rates for patients with AV conduction disease. In contrast to HBP, LBBAP success rates remain high over the entire spectrum of AV conduction disease, and lead parameters remain stable during follow-up.

Keywords: Atrioventricular block; Conduction system pacing; His-bundle pacing; Left bundle branch area pacing; Physiological pacing.

PubMed Disclaimer

Publication types

LinkOut - more resources