Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2022 Nov;80(6):827-836.
doi: 10.1016/j.pharma.2022.05.001. Epub 2022 May 11.

Assessment of insulin adherence in diabetic outpatients: An observational study

Affiliations
Observational Study

Assessment of insulin adherence in diabetic outpatients: An observational study

J Despras et al. Ann Pharm Fr. 2022 Nov.

Abstract

Objectives: In the management of diabetic patients on insulin therapy, adherence to medication is a key element for avoiding chronic complications. The purpose of this study was to evaluate diabetic patients' ability to translate glycemic results into an appropriate insulin dose and thus, adherence to insulins.

Methods: This was an observational, retrospective, monocentric pilot study. Diabetic patients on insulin therapy being followed at the metabolic and endocrine diseases department were divided into two groups depending on their mode of glycemic control at home: capillary glycemia (Notebook group) or interstitial glycemia using the FreeStyle Libre® flash system (FSL group). Adherence was assessed based on the rate of compliance in adapting insulin doses to the prescribed protocols (depending on type of insulin, glycemic targets, and patients' characteristics) by a pharmacy resident and a senior diabetologist. Good adherence was defined as a minimum rate of 80% of conforming insulin injections for each patient.

Results: A total of 50 patients were included, 35 in the Notebook group and 15 in the FSL group. Two-thirds of patients were non-adherent to insulin. Dose adjustment errors mainly concerned rapid-acting insulin with 51.1% of non- conformities, 10.0% of which were due to underdosing in the Notebook group and 21.7% to overdosing in the FSL group. Hyperglycemia was predominant in both populations with a median time in range of 19.0% in the FSL group and well below recommendations (>70%).

Conclusions: Despite the use of increasingly efficient, easy-to-use devices in diabetes monitoring, insulin non-adherence and glycemic imbalance are unresolved major issues. Diabetic patients require reinforced medical follow-up for optimal insulin management.

Keywords: Autosurveillance glycémique; Clinical pharmacy; Diabetes mellitus; Diabète; Insulin; Insuline; Medication adherence; Observance médicamenteuse; Pharmacie clinique; Self-monitoring of blood glucose.

PubMed Disclaimer

Publication types

LinkOut - more resources