Restorative angle of zirconia restorations cemented on non-original titanium bases influences the initial marginal bone loss: 5-year results of a prospective cohort study
- PMID: 35570366
- PMCID: PMC9543966
- DOI: 10.1111/clr.13954
Restorative angle of zirconia restorations cemented on non-original titanium bases influences the initial marginal bone loss: 5-year results of a prospective cohort study
Abstract
Aim: To assess radiographic, restorative, clinical and technical outcomes as well as patient satisfaction of directly veneered zirconia restorations cemented on non-original titanium bases over 5 years.
Material and methods: Twenty-four patients with a single missing tooth in the aesthetic zone were recruited. All patients received a two-piece implant with a screw-retained veneered zirconia restoration cemented extraorally on a titanium base abutment. Marginal bone levels (MBL), marginal bone changes, technical complications, patient satisfaction and clinical parameters including probing depth, bleeding on probing and plaque index were assessed at crown delivery (baseline), at 1 year (FU-1) and 5 years (FU-5) of follow-up. To investigate the relationship between restorative angle and MBL as well as marginal bone changes (bone loss/bone gain), correlation tests and linear regression models were carried out.
Results: Twenty-two patients were available for re-examination at 5 years. The mean MBL amounted to 0.54 ± 0.39 mm at baseline, and to 0.24 ± 0.35 at FU-5 (=bone gain) (p < .001). At FU-1, a positive correlation (r = .5) between the mesial restorative angle and mesial MBL was found (p = .012). Marginal bone changes between baseline and FU-1 at mesial sites were also positively correlated with the mesial restorative angle (r = .5; p = .037). Linear and logistic regression models confirmed that mesial marginal bone loss was significantly associated with the mesial restorative angle at FU-1 (p < .05). At 5 years, these significant associations at mesial sites disappeared (p > .05). At distal sites, no correlations or associations between the restorative angle and MBL or marginal bone changes were found regardless of the time point. During the 5-year follow-up, 5 technical complications occurred, mainly within the first year and mostly chippings. All patients were entirely satisfied with their implant-supported restoration at 5 years.
Conclusion: Within the limitations of the present study, the restorative angle of implant-supported crowns on non-original titanium bases might influence the initial marginal bone loss but without affecting their favourable long-term clinical performance. A restorative angle of <40° may limit the initial marginal bone loss at implant-supported crowns with titanium bases.
Keywords: CAD/CAM; dental implant-abutment design; dental implants; material testing; prosthodontics; titanium; zirconium.
© 2022 The Authors. Clinical Oral Implants Research published by John Wiley & Sons Ltd.
Conflict of interest statement
All authors declare to have no conflict of interest.
Figures
References
-
- Albrektsson, T. , Zarb, G. , Worthington, P. , & Eriksson, A. R. (1986). The long‐term efficacy of currently used dental implants: A review and proposed criteria of success. The International Journal of Oral & Maxillofacial Implants, 1(1), 11–25. - PubMed
-
- Berglundh, T. , Armitage, G. , Araujo, M. G. , Avila‐Ortiz, G. , Blanco, J. , Camargo, P. M. , Chen, S. , Cochran, D. , Derks, J. , Figuero, E. , Hämmerle, C. H. F. , Heitz‐Mayfield, L. J. A. , Huynh‐Ba, G. , Iacono, V. , Koo, K. T. , Lambert, F. , McCauley, L. , Quirynen, M. , Renvert, S. , … Zitzmann, N. (2018). Peri‐implant diseases and conditions: Consensus report of workgroup 4 of the 2017 world workshop on the classification of periodontal and peri‐implant diseases and conditions. Journal of Clinical Periodontology, 45(Suppl 20), S286–S291. 10.1111/jcpe.12957 - DOI - PubMed
-
- Broggini, N. , McManus, L. M. , Hermann, J. S. , Medina, R. U. , Oates, T. W. , Schenk, R. K. , Buser, D. , Mellonig, J. T. , & Cochran, D. L. (2003). Persistent acute inflammation at the implant‐abutment interface. Journal of Dental Research, 82(3), 232–237. 10.1177/154405910308200316 - DOI - PubMed
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous