Modification and evaluation of a multichannel blood cell counting system for blood analysis in veterinary hematology
Abstract
A multichannel, semiautomated, blood cell counting system (Coulter Counter Model S550) was modified for use in veterinary hematology by increasing both the erythrocyte and leukocyte aperture currents to 225 V and 195 V, respectively, followed by calibration with human blood. It was evaluated by use of 350 samples from dogs, cats, horses, and cows. Values for leukocyte count, erythrocyte count, mean corpuscular volume, and hematocrit generated by the S550 were compared with values generated by an automated multichannel counter with histogram capability and other reference procedures when appropriate. Mean differences for values between S550 and reference values were less than calibration tolerance limits for the instrument. Correlation coefficients were excellent for all values of each species. To assess behavior of leukocytes of the different species with respect to the counting threshold, leukocyte size distribution histograms were generated for all samples analyzed on the S550. Means for mean leukocyte volumes in diluent and lysing reagents were 55.5, 56.6, 67.4, and 72.8 fl for dogs, cats, horses, and cows, respectively. Canine leukocyte counts, because of small leukocyte size, were an average of 14% less for 5 samples analyzed on the unmodified instrument, compared with analysis after increasing the leukocyte aperture current. Leukocyte threshold failures attributable to interfering particles, resulting in falsely high counts, were recognized in 14%, 10%, 8% and 0% of feline, bovine, canine, and equine samples, respectively. The magnitude of error in these samples averaged 5% for cows and dogs, but was considered not important. However, leukocyte counts of feline samples in this group averaged 44% falsely high.
Similar articles
-
Erythrocyte volume distribution analysis in healthy dogs, cats, horses, and dairy cows.Am J Vet Res. 1982 Jan;43(1):163-6. Am J Vet Res. 1982. PMID: 7091812
-
Size referenced electronic leukocyte counting threshold and lysed leukocyte size distribution of common domestic animal species.Vet Pathol. 1987 Nov;24(6):560-3. doi: 10.1177/030098588702400615. Vet Pathol. 1987. PMID: 3455085
-
[Experiences with the QBC-V hematology system at the veterinary hospitals of Zurich and Bern].Schweiz Arch Tierheilkd. 1990;132(5):261-6. Schweiz Arch Tierheilkd. 1990. PMID: 2389140 German.
-
Hematology of the normal dog and cat.Vet Clin North Am Small Anim Pract. 1981 May;11(2):209-17. doi: 10.1016/s0195-5616(81)50027-1. Vet Clin North Am Small Anim Pract. 1981. PMID: 7032044 Review. No abstract available.
-
Quality control of multichannel haematology analysers: critique of current methods and the need for performance goals.Clin Lab Haematol. 1990;12 Suppl 1:3-12. Clin Lab Haematol. 1990. PMID: 2282763 Review.
Cited by
-
A flow cytometric method for determination of the blood neutrophil fraction in rats.J Am Assoc Lab Anim Sci. 2009 Mar;48(2):152-6. J Am Assoc Lab Anim Sci. 2009. PMID: 19383211 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous